Czasopisma
Czasopisma
Czasopisma
ATEST - OCHRONA PRACY
ATEST - OCHRONA PRACY
AURA
AURA
AUTO MOTO SERWIS
AUTO MOTO SERWIS
CHEMIK
CHEMIK
CHŁODNICTWO
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
Czasopisma
Czasopisma
Czasopisma
GAZETA CUKROWNICZA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
OCHRONA PRZED KOROZJĄ
Czasopisma
Czasopisma
Czasopisma
ODZIEŻ
ODZIEŻ
OPAKOWANIE
OPAKOWANIE
PACKAGING REVIEW
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PAPIERNICZY
Czasopisma
Czasopisma
Czasopisma
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH
WOKÓŁ PŁYTEK CERAMICZNYCH
Menu
Menu
Menu
Prenumerata
Prenumerata
Publikacje
Publikacje
Drukarnia
Drukarnia
Kolportaż
Kolportaż
Reklama
Reklama
O nas
O nas
ui-button
Twój Koszyk
Twój koszyk jest pusty.
Niezalogowany
Niezalogowany
Zaloguj się
Zarejestruj się
Reset hasła
Czasopismo
|
PRZEGLĄD ELEKTROTECHNICZNY
|
Rocznik 2016 - zeszyt 2
Lightning Induced Ventricular Fibrillation risk during wandering
10.15199/48.2016.02.31
Jarosław WIATER
nr katalogowy: 96931
10.15199/48.2016.02.31
Wandering is a popular way of spending leisure time especially for the urban population. Health problems arising from such outdoor recreational activities are better understood today and may improve survival in case of accidents if sufficient awareness of clinical staff is established. The purpose of this paper is to shed light on this physiological phenomenon by investigating the connection between the physics associated with lightning strikes and the physiological response of the human body. From the results a minimum safety-distance from different trees species is derived. Flat rooted trees are more dangerous than tap rooted trees. In the worst case it may be considered safe if a distance of at least 25 meters to tree trunks is maintained. Streszczenie. Turystyka piesza jest popularnym sposobem spędzania wolnego czasu, szczególnie dla mieszkańców miast. Problemy zdrowotne wynikające z tej aktywności są dobrze poznane, ale w szczególnych przypadkach wiedza o zagrożeniu może być pomocna i może się przyczynić do zwiększenia szans na przeżycie. Celem tej publikacji jest pokazanie związku pomiędzy wyładowaniem piorunowym a reakcją organizmu ludzkiego. Na podstawie otrzymanych wyników wyznaczono bezpieczny odstęp od drzew podczas wyładowań piorunowych. Drzewa z systemem poziomym systemem korzeniowym stwarzają większe zagrożenie niż drzewa z systemem palowym. W najgorszym przypadku bezpieczny odstęp od pnia drzewa wynosić powinien co najmniej 25 metrów. (Ryzyko fibrylacji komór serca turystów pieszych wywołane wyładowaniem piorunowym). Keywords: wandering, lightning strike, thunderstorm, safe distance. Słowa kluczowe: turystyka piesza, wyładowanie doziemne, burza, bezpieczna odległość. Introduction The National Oceanic and Atmospheric Administration (NOAA), International Lightning Safety Initiative (NLSI) and National Outdoor Leadership Scholl (NOLS) point out that lighting safety for people is a global issue[1]. According to Holle, there ar[...]
Bibliografia
[1] NLSI International Lightning Safety Initiative. 2014. http://www.lightningsafety.com/nlsi_history/intl_safety_initiative. html [2] Ronald L Holle. Activities and locations of recreation deaths and injuries from lightning. Royal Aeronautical Society 2003. http://www.lightning-strike.org/Portals/20a4c8c2-6f09-4d50- a98a-08365ce9e232/library/103-77KMI-Holle.pdf [3] NWS Lightning Safety Outdoors. http://www.lightningsafety.noaa.gov/outdoors.htm [4] John Gookin. NOLS Backcountry Lightning Safety Guidelines. http://rendezvous.nols.edu/files/Curriculum/research_projects/R isk%20Management%20Reports/NOLS%20Backcountry%20Li ghtning%20Safety%20Guidelines.pdf [5] Deborah R. Levy, Toshio Akiyama. Lightning-induced ventricular fibrillation. Cardiology Journal 2007, Vol. 14, No.1, pp. 91-95 [6] Dronacharya L, Poudel R. Lightning induced atrial fibrillation. Kathmandu University Medical Journal (2008), Vol. 6, No. 4, Issue 24, pp. 514-515 [7] Lichtenberg R, Dries D. Cardiovascular Effects of Lightning Strikes. JACC Vol. 21, No.2, February 1993, pp. 531-6 [8] Karadas S,Vurusjan E, Dursun R, Sincer I, Gonullu H, Akkaya E. Myocardial infarction due lightning strike. JPMA September 2013, pp. 1186-8 [9] Pfortmueller CA, Yikun Y, Haberkern M, Wuest E, Zimmermann H, Exadaktylos AK. Injuries, sequelae, and treatment of lightning induced injuries: 10 years of experience at a Swiss trauma center. Emerg Med Int 2012; 2012: Article ID167698. doi:10.1155/2012/167698 [10] Cooper MA. A fifth mechanism of lightning injury. Acad Emerg Med 2002; 9: 172-4 [11] Cooper MA, Holle RL, Andrews C. Distribution of lightning injury mechanisms. 20th International Lightning Detection Conference 2008. [12] Cooray V. Lightning Protection. Institution of Engineering and Technology 2010. [13] Uman MA. The Art and Science of Lightning Protection. Cambridge University Press 2008. [14] DEHN + SÖHNE. Lightning Protection Guide. Neumarkt Germany 2007. [15] IEC 61312-1:1995. Protection against lightning electromagnetic impulse - Part 1: General principles. [16] IEC 62305-1:Ed2:2010-12. Protection against lightning - Part 1: General principles. [17] Thomson EM. The dependence of lightning return stroke characteristics on latitude. Journal of Geophysical Research, 1980, 85:1050-56. [18] Heidler F, Hopf C. Measurement results of the electric fields in cloud-to-ground lightning in nearby Munich, Germany. IEEE Transactions on Electromagnetic Compatibility 1998;40(4):436-43. [19] Thottappillil R, Rakov VA, Uman MA, Beasley WH, Master MJ, Shelukhin DV. Lightning subsequent-stroke electric field peak greater than the first stroke peak and multiple ground teminations. Journal of Geophysical Research, 992;97(D7):7503-509. [20] Cooray V, Perez H. Some features of lightning flashes observed in Sweden. Journal of Geophysical Research, 1994;99(D5): 10683-88. [21] Cooray V, Jayaratne KP. Characteristics of lightning flashes observed in Sri Lanka in the tropics. Journal of Geophysical Research, 1994;99(D10): 21051-65. [22] Rakov V.A., Uman M.A., Thottappillil R. Review of lightning properties from electric field and TV observations. Journal of Geophysical Research, 1994;99:10745-50. [23] Qie Xiushu, Ye Yu, Daohong Wang, Huibin Wang, Rongzhong Chu. Characteristics of cloud-to-ground lightning in Chinese Inland Plateau notes and correspondence. Journal of the Meteorological Society of Japan, 2002;80(4):745-54. [24] Miranda FJ, de Pinto OJr, Saba MMF. A study of the time interval between return strokes and K-changes of negative cloud-to-ground lightning flashes in Brazil. Journal of Atmospheric and Solar-Terrestrial Physics, 2003;65:293-97. [25] Saba MMF, Ballarotti MG, Pinto OJr. Negative cloud-toground lightning properties from high-speed video observations. Journal of Geophysical Research, 2006;111:D03101. [26] Zafren K, Durrer B, Herry JP, Brugger H. Lightning injuries: prevention and on-site treatment in mountains and remote ares. Resuscitation 65 (2005), pp. 369-372. [27] IEEE Std 80-2002: IEEE Guide for Safety in AC Substation Grounding. [28] Gale MR, Grigal DF. Vertical root distributions of northern tree species in relation to successional status. Canadian Journal of Forest Research, 1987, 17(8): 829-834, 10.1139/x87-131. [29] Sowa A.W.: Ochrona urządzeń oraz systemów elektronicznych przed narażeniami piorunowymi. Rozprawy Naukowe Nr 219. Oficyna Wydawnicza Politechniki Białostockiej, Białystok 2011, Poland. [30] IEC 60364. Electrical Installations for Buildings [31] IEC 61000-4-2 ed2. Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test. [32] IEC/TS 60479-2 ed3. Effects of current on human beings and livestock - Part 2: Special aspects. [33] Neuhaus H: Blitzschutzanlagen: Erlauterungen zu DIN 57 185/VDE 0185. 1. Aufl. Berlin; Offenbach: VDE-Verlag, 1983. [34] Dalziel A., Charles F., Lee W.R.: Reevaluation of Lethal Electric Currents. In: IEEE Tran. Ind. Gen. Apple IGA-4 (1968), Nr. 5; pp. 467-476. [35] http://www.nlm.nih.gov/research/visible/visible_human .html The National Library of Medicine's Visible Human Project. [36] Flisowski Z.: Trendy rozwojowe ochrony odgromowej budowli. Część I. Wyładowania piorunowe jako źródło zagrożenia. PWN, Warszawa 1986, Poland. [37] CDEGS Current Distribution, Electromagnetic Interference, Grounding and Soil Structure Analysis. Safe Engineering Services & Technologies Ltd., Montreal Canada. [38] IEC 62305-3:2005, Protection against lightning - Part 3. Physical damage to structure and life hazard. [39] http://commons.wikimedia.org/wiki/File:EKG_Complex_e n.svg#mediaviewer/File:EKG_Complex_en.svg
Treść płatna
Jeśli masz wykupiony/przyznany dostęp -
zaloguj się
.
Skorzystaj z naszych propozycji zakupu!
Publikacja
e-Publikacja (format pdf) - nr 96931 "Lightning Induced Ventric..."
licencja: Osobista
Produkt cyfrowy
10.00 zł
Do koszyka
Zeszyt
PRZEGLĄD ELEKTROTECHNICZNY - e-zeszyt (pdf) 2016-2
licencja: Osobista
Produkt cyfrowy
55.00 zł
Do koszyka
Prenumerata
PRZEGLĄD ELEKTROTECHNICZNY - prenumerata cyfrowa
licencja: Osobista
Produkt cyfrowy
Nowość
762.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS (Prenumerata papierowa + dostęp do portalu sigma-not.pl + e-prenumerata)
1002.00 zł brutto
927.78 zł netto
74.22 zł VAT
(stawka VAT 8%)
1002.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna + wysyłka
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna
960.00 zł brutto
888.89 zł netto
71.11 zł VAT
(stawka VAT 8%)
PRZEGLĄD ELEKTROTECHNICZNY - pakowanie i wysyłka
42.00 zł brutto
34.15 zł netto
7.85 zł VAT
(stawka VAT 23%)
1002.00 zł
Do koszyka
Zeszyt
2016-2
Czasopisma
ATEST - OCHRONA PRACY
AURA
AUTO MOTO SERWIS
CHEMIK
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
ODZIEŻ
OPAKOWANIE
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH