Czasopisma
Czasopisma
Czasopisma
ATEST - OCHRONA PRACY
ATEST - OCHRONA PRACY
AURA
AURA
AUTO MOTO SERWIS
AUTO MOTO SERWIS
CHEMIK
CHEMIK
CHŁODNICTWO
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
Czasopisma
Czasopisma
Czasopisma
GAZETA CUKROWNICZA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
OCHRONA PRZED KOROZJĄ
Czasopisma
Czasopisma
Czasopisma
ODZIEŻ
ODZIEŻ
OPAKOWANIE
OPAKOWANIE
PACKAGING REVIEW
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PAPIERNICZY
Czasopisma
Czasopisma
Czasopisma
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH
WOKÓŁ PŁYTEK CERAMICZNYCH
Menu
Menu
Menu
Prenumerata
Prenumerata
Publikacje
Publikacje
Drukarnia
Drukarnia
Kolportaż
Kolportaż
Reklama
Reklama
O nas
O nas
ui-button
Twój Koszyk
Twój koszyk jest pusty.
Niezalogowany
Niezalogowany
Zaloguj się
Zarejestruj się
Reset hasła
Czasopismo
|
MATERIAŁY BUDOWLANE
|
Rocznik 2022 - zeszyt 11
Odporność ogniowa stalowych elementów rozciąganych zabezpieczonych ogniochronnie
Fire resistance of tensile fire-protected steel elements
10.15199/33.2022.11.59
Piotr Turkowski
nr katalogowy: 140622
10.15199/33.2022.11.59
Streszczenie
W artykule zaprezentowano wyniki badania odporności ogniowej stalowego kształtownika o profilu IPE przy działaniu siły rozciągającej i podobnego elementu nieobciążonego. Elementy zabezpieczono ogniochronnie farbą pęczniejącą. W trakcie badania prowadzono pomiar temperatury obu elementów stalowych i wydłużenia elementu obciążonego. Wpływ obciążenia ustalono na podstawie czasu osiągnięcia kolejnych wartości temperatury projektowej, za pomocą tzw. współczynnika korekcyjnego. Uzyskane wyniki pokazują, że nieskuteczność systemu ogniochronnego, określona na elementach zginanych, jest znacznie większa niż możliwa do osiągnięcia na elementach rozciąganych. W celu określenia, jak duża jest to różnica, konieczne jest przeprowadzenie badań odporności ogniowej. Obliczony spadek skuteczności ogniochronnej wynosił ok. 50%, co wskazuje na konieczność mocniejszych, niż wskazane w niemieckich przepisach, ograniczeń stosowania izolacji na elementach rozciąganych.
Abstract
This study presents the results of fire resistance tests of an IPE steel profile under tensile force, and of a similar unloaded element. The elements were protected against fire with intumescent paint. During the test, the temperature of both steel elements and the elongation of the loaded element were measured. The effects of load were determined based on times to reach specific design temperatures with the use of the so- called "correction factor". The obtained results demonstrate that a direct transfer of results from fire protection system effectiveness tests conducted on bent elements onto tensile ones is impossible. The calculated reduction in fire protection effectiveness was approx. 50%, which points to the need for stricter restrictions on the application of fire protection onto tensile elements than those present in German legislation.
Słowa kluczowe
element rozciągany
odporność ogniowa
zabezpieczenie ogniochronne
farby pęczniejące.
Keywords
tensile element
fire resistance
fire protection
intumescent paints.
Bibliografia
[1] Kotsovinos K, Rackauskaite E, Deeny S. The role of transfer beams on the global structural fire response of tall steel framed buildings. Fire Saf. J. 2020; https://doi.org/10.1016/j.firesaf. 2020.103172. [2] Wang W, Kodur V. Tensile test on steels at elevated temperatures, in: Mater. Prop. Steel Fire Cond. 2020; https://doi. org/10.1016/b978-0-12- 813302-6.00003-5. [3] Franssen JM. Calculation of temperature in fire-exposed bare steel structures: Comparison between ENV 1993-1-2 and en 1993-1-2, Fire Saf. J. 2006; https://doi.org/10.1016/j.firesaf.2005.11.007. [4] Sun R, Huang Z, Burgess IW. Progressive collapse analysis of steel structures under fire conditions, Eng. Struct. 2012; https://doi. org/10.1016/j. engstruct. 2011.10.009. [5] Molkens T, Rossi B. On the Simulation of Real Fire for Post Fire Resistance Evaluation of Steel Structures, Springer US, 2020. https://doi. org/10.1007/s10694-020-01025-6. [6] Franssen J-M, Kodur V, Zaharia R. Designing Steel Structures for Fire Safety, CRC Press, 2009. https://doi.org/10.1201/9780203875490. [7] CEN, EN 13381-10:2020. Test methods for determining the contribution to the fire resistance of structural members – Part 10: Applied protection to solid steel bars in tension, (2020). [8] CEN, ENV 13381-4:2002. Test methods for determining the contribution to the fire resistance of structural members. Applied protection to steel members, (2002). [9] CEN, EN 13381-4:2013. Test methods for determining the contribution to the fire resistance of structural members. Applied passive protection products to steel members, (2013). [10] CEN, EN 13381-8:2013. Test methods for determining the contribution to the fire resistance of structural members. Applied reactive protection to steel members, (2013). [11] Mesquita L, Piloto P, Roque S, Vaz M. Fire resistance of steel members protected with intumescent coatings, YIC2012 – First ECCOMAS Young Investig. Conf. 2012. [12] CEN, EN 1993-1-2:2005. Eurocode 3. Design of steel structures. General rules. 2005. [13] CEN, EN 1993-1-1:2005+A1: 2014. Eurocode 3. Design of steel structures. General rules and rules for buildings. 2014. [14] Łukomski M, Turkowski P, Roszkowski P, Papis B. Fire Resistance of Unprotected Steel Beams-Comparison between Fire Tests and Calculation Models, Procedia Eng. 2017; 172: 665 – 672. https://doi.org/10.1016/j.proeng. 2017.02.078. [15] Hothan S, Grundlagen zur Erweiterung des Anwendungsbereiches für reaktive Brandschutzsysteme auf Stahlbauteilen im nationalen Zulassungsverfahren, DIBt Mitteilungen. 2011; 42: 187 – 189. https://doi. org/10.1002/dibt. 201130046. [16] Häßler D, Hothan S. Numerical and experimental analysis of reactive fire protection systems applied to solid steel rods in tension. J. Struct. Fire Eng. 2015; 6: 275 – 282. https://doi. org/10.1260/2040-2317.6.4.275. 17] Häßler M, Häßler D, Hothan S, Krüger S. Fire tests of steel tension rod systems with intumescent coating, J. Struct. Fire Eng. 2019; 22 – 32; https://doi. org/10.1108/JSFE-01-2019-0005. [18] Stopp V, Proschek P. Reaktive Brandschutz- systeme auf Stahlbauteilen mit reiner Zugbeanspruchung, DIBt Mitteilungen. 2011; https://doi. org/10.1002/dibt. 201130045. [19] Hothan S, Häßler D. Summary of the German national regulations regarding the scope of application of intumescent (reactive) fire protection coatings on steel tension members, (2020). [20] DIN, German proposal for determining the fire resistance of steel tension bars with fire protection systems based on mechanically loaded fire tests (NA 005-52-02 AA), (2015). [21] Mróz K, Hager I, Korniejenko K. Material Solutions for Passive Fire Protection of Buildings and Structures and Their Performances Testing, Procedia Eng. 2016; 151: 284 – 291. https://doi. org/10.1016/j.proeng.2016.07.388. 22] P. Sulik, Bierne zabezpieczenia przeciwpożarowe konstrukcji, Izolacje. 2018; 3: 118 – 122. [23] Anderson CE, Dziuk J, Mallow WA, Buckmaster J. Intumescent reaction mechanisms. 1985; https://doi.org/10.1177/073490418500300303. [24] Lucherini A, Torero JL, Maluk C. Effects of substrate thermal conditions on the swelling of thin intumescent coatings, Fire Mater. 2020; 1–14. https://doi.org/10.1002/fam.2840. [25] de Silva D, Bilotta A, Nigro E. Approach for modelling thermal properties of intumescent coating applied on steel members. Fire Saf. J. 2020; 116: 103200. https://doi.org/10.1016/j.firesaf. 2020.103200. [26] CEN, EN 1363-1:2020. Fire resistance tests. General requirements. 2020.
Treść płatna
Jeśli masz wykupiony/przyznany dostęp -
zaloguj się
.
Skorzystaj z naszych propozycji zakupu!
Publikacja
e-Publikacja (format pdf) - nr 86336 "Montaż wielkoformatowych ..."
licencja: Osobista
Produkt cyfrowy
10.00 zł
Do koszyka
Zeszyt
MATERIAŁY BUDOWLANE- e-zeszyt (pdf) 2022-11
licencja: Osobista
Produkt cyfrowy
Nowość
27.00 zł
Do koszyka
Prenumerata
WOKÓŁ PŁYTEK CERAMICZNYCH - prenumerata cyfrowa
licencja: Osobista
Produkt cyfrowy
Nowość
100.00 zł
Do koszyka
WOKÓŁ PŁYTEK CERAMICZNYCH - papierowa prenumerata roczna + wysyłka
licencja: Osobista
Szczegóły pakietu
Nazwa
WOKÓŁ PŁYTEK CERAMICZNYCH - papierowa prenumerata roczna
100.00 zł brutto
92.59 zł netto
7.41 zł VAT
(stawka VAT 8%)
WOKÓŁ PŁYTEK CERAMICZNYCH - pakowanie i wysyłka
14.00 zł brutto
11.38 zł netto
2.62 zł VAT
(stawka VAT 23%)
114.00 zł
Do koszyka
WOKÓŁ PŁYTEK CERAMICZNYCH - PAKIET prenumerata PLUS
licencja: Osobista
Szczegóły pakietu
Nazwa
WOKÓŁ PŁYTEK CERAMICZNYCH - PAKIET prenumerata PLUS (Prenumerata papierowa + dostęp do portalu sigma-not.pl + e-prenumerata)
150.00 zł brutto
138.89 zł netto
11.11 zł VAT
(stawka VAT 8%)
150.00 zł
Do koszyka
Zeszyt
2022-11
Czasopisma
ATEST - OCHRONA PRACY
AURA
AUTO MOTO SERWIS
CHEMIK
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
ODZIEŻ
OPAKOWANIE
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH