Czasopisma
Czasopisma
Czasopisma
ATEST - OCHRONA PRACY
ATEST - OCHRONA PRACY
AURA
AURA
AUTO MOTO SERWIS
AUTO MOTO SERWIS
CHEMIK
CHEMIK
CHŁODNICTWO
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
Czasopisma
Czasopisma
Czasopisma
GAZETA CUKROWNICZA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
OCHRONA PRZED KOROZJĄ
Czasopisma
Czasopisma
Czasopisma
ODZIEŻ
ODZIEŻ
OPAKOWANIE
OPAKOWANIE
PACKAGING REVIEW
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PAPIERNICZY
Czasopisma
Czasopisma
Czasopisma
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH
WOKÓŁ PŁYTEK CERAMICZNYCH
Menu
Menu
Menu
Prenumerata
Prenumerata
Publikacje
Publikacje
Drukarnia
Drukarnia
Kolportaż
Kolportaż
Reklama
Reklama
O nas
O nas
ui-button
Twój Koszyk
Twój koszyk jest pusty.
Niezalogowany
Niezalogowany
Zaloguj się
Zarejestruj się
Reset hasła
Czasopismo
|
PRZEGLĄD ELEKTROTECHNICZNY
|
Rocznik 2023 - zeszyt 9
Energy-Efficient Network Architecture for Smart City Development
Energooszczędna architektura sieci dla rozwoju inteligentnych miast
10.15199/48.2023.09.25
Ashwini JAYADEYAN
Ida Syafiza MD ISA
Mohd Riduan AHMAD
Nur Latif Azyze MOHD SHAARI AZYZE
Norasida Farahizzaty RASIDI
Nur Hidayah ZAINAN
nr katalogowy: 145247
10.15199/48.2023.09.25
Streszczenie
The growing number of objects connected to the Internet due to the evolution of smart cities development and the tremendous data in the future 6G networks with extensive processing has produced massive amounts of data that need to be processed. This will burden the conventional clouds to process the data besides reducing the Quality of Services due to high latency. Also, the increase in data volumes increased the energy consumed by transport networks and the cloud. Therefore, fog computing has been introduced to overcome the limitation of the cloud. This study proposed a new fog computing architecture for Internet-of-Things (IoT) applications based on wireless access networks using WiFi technology. A new mathematical model has been developed to optimize the number and locations of the fog servers at the access network to minimize the energy consumption of the networking and processing equipment at the access layer. This is beneficial for smart city development which contributes to the 2030 Agenda for Sustainable Development Goals (SDG) under Goal 7. The Mixed Integer Linear Programming (MILP) model using AMPL software with CPLEX solver is used to model the energy-efficient fog computing architecture considering twelve tourist locations in Melaka as the case study. The results show that the proposed optimized approach (OA) has 52.6% energy saving as the low number of fog servers and networking devices are utilized in the network compared to the non-optimized approach (NOA). Besides, the energy saving increased up to 81.1% when high processing server capacity is considered in the network. In addition to that, the results also show that increasing the traffic demands by each user does not give a significant energy increment when considering a fog server with high processing capacity in the network
Abstract
Rosnąca liczba obiektów podłączonych do Internetu w wyniku ewolucji rozwoju inteligentnych miast i ogromne ilości danych w przyszłych sieciach 6G z ekstensywnym przetwarzaniem wytworzyły ogromne ilości danych, które trzeba przetworzyć. To obciąży konwencjonalne chmury do przetwarzania danych, oprócz obniżenia jakości usług z powodu dużych opóźnień. Również wzrost wolumenu danych spowodował wzrost zużycia energii przez sieci transportowe i chmurę. Dlatego w celu przezwyciężenia ograniczeń chmury wprowadzono obliczenia mgły. W badaniu tym zaproponowano nową architekturę mgły obliczeniowej dla aplikacji Internet-of-Things (IoT) w oparciu o sieć dostępu bezprzewodowego wykorzystującą technologię WiFi. Opracowano nowy model matematyczny w celu optymalizacji liczby i lokalizacji serwerów mgły w sieci dostępowej, aby zminimalizować zużycie energii przez sprzęt sieciowy i przetwarzający w warstwie dostępowej. Jest to korzystne dla rozwoju inteligentnych miast, które przyczyniają się do realizacji Agendy na rzecz celów zrównoważonego rozwoju 2030 (SDG) w ramach celu 7. Model programowania liniowego mieszanych liczb całkowitych (MILP) z wykorzystaniem oprogramowania AMPL z solverem CPLEX jest wykorzystywany do modelowania energooszczędnej architektury przetwarzania mgły z uwzględnieniem dwanaście miejsc turystycznych w Melace jako studium przypadku. Wyniki pokazują, że proponowane zoptymalizowane podejście (OA) zapewnia 52,6% oszczędności energii, ponieważ w sieci wykorzystywana jest niewielka liczba serwerów mgły i urządzeń sieciowych w porównaniu z podejściem niezoptymalizowanym (NOA). Poza tym oszczędność energii wzrosła do 81,1%, gdy w sieci uwzględniono wysoką wydajność serwerów przetwarzających. Oprócz tego wyniki pokazują również, że zwiększenie zapotrzebowania na ruch przez każdego użytkownika nie daje znaczącego przyrostu energii, biorąc pod uwagę serwer mgły o dużej mocy obliczeniowej w sieci.
Słowa kluczowe
Fog computing
energy efficiency
Internet of Things
wireless network
WiFi technology
Keywords
Obliczenia mgły
efektywność energetyczna
Internet rzeczy
sieć bezprzewodowa
technologia WiFi
Bibliografia
[1] “EXCECUTIVE SUMMARY MALAYSIA: SMART CITY FRAMEWORK,” 2018. [2] TWI Ltd (Head Office), “What is a smart city? – Definition and Examples,” TWI Ltd (Head Office), 2022. https://www.twi global.com/technical-knowledge/faqs/what-is-a-smartcity#WhySmartCitiesAreImportant. [3] J. Morley, K. Widdicks, and M. Hazas, “Energy Research & Social Science Digitalisation , energy and data demand : The impact of Internet tra ffi c on overall and peak electricity consumption,” Energy Res. Soc. Sci., vol. 38, no. January, pp. 128–137, 2018, doi: 10.1016/j.erss.2018.01.018. [4] DagangNews.com, “Malaysia Data Center Market Size to Cross RM3,409m by 2025,” July, 2020. https://dagangnews.com/malaysia-data-center-market-sizecross-rm3409m-2025. [5] Anders S. G. Andrae and Tomas Edler, “On Global Electricity Usage of Communication Technology: Trends to 2030,” challenges, pp. 117–157, 2015, doi: 10.3390/challe6010117. [6] W. Van Heddeghem, S. Lambert, B. Lannoo, D. Colle, M. Pickavet, and P. Demeester, “Trends in worldwide ICT electricity consumption from 2007 to 2012,” Comput. Commun., vol. 50, pp. 64–76, 2014, doi: 10.1016/j.comcom.2014.02.008. [7] C. Mouradian et al., “A Comprehensive Survey on Fog Computing : State-of-the-Art and Research Challenges,” IEEE Commun. Surv. Tutorials, vol. 20, no. 1, pp. 416–464, 2018, doi: 10.1109/COMST.2017.2771153. [8] I. S. M. Isa, T. E. H. El-Gorashi, M. O. I. Musa, and J. M. H. Elmirghani, “Energy efficient fog based healthcare monitoring infrastructure,” IEEE Access, vol. 8, pp. 197828–197852, 2020, doi: 10.1109/access.2020.3033555. [9] I. S. M. Isa, N. S. Kamaruzaman, and N. L. A. Shaari, “DEVELOPMENT OF REAL-TIME LoRA-BASED AIR POLLUTION MONITORING SYSTEM,” ARPN J. Eng. Appl. Sci., vol. 16, no. 19, pp. 1984–1990, 2021. [10] I. S. B. M. Isa and A. Hanani, “Development of real-time indoor human tracking system using LoRa technology,” Int. J. Electr. Comput. Eng., vol. 12, no. 1, pp. 845–852, 2022, doi: 10.11591/ijece.v12i1.pp845-852. [11] N. L. A. M. S. Azyze, I. S. M. Isa, and T. S. Chin, “IoT-based communal garbage monitoring system for smart cities,” Indones. J. Electr. Eng. Comput. Sci., vol. 27, no. 1, pp. 37– 43, 2022, doi: 10.11591/ijeecs.v27.i1.pp37-43. [12] J. Ren, G. Yu, Y. He, and G. Y. Li, “Collaborative Cloud and Edge Computing for Latency Minimization,” IEEE Trans. Veh. Technol., vol. 68, no. 5, pp. 5031–5044, 2019, doi: 10.1109/TVT.2019.2904244. [13] S. He et al., “Cloud-Edge Coordinated Processing: LowLatency Multicasting Transmission,” IEEE J. Sel. Areas Commun., vol. 37, no. 5, pp. 1144–1158, 2019, doi: 10.1109/JSAC.2019.2906791. [14] C. Yang, S. Lan, L. Wang, W. Shen, and G. G. Q. Huang, “Big data driven edge-cloud collaboration architecture for cloud manufacturing: A software defined perspective,” IEEE Access, vol. 8, pp. 45938–45950, 2020, doi: 10.1109/ACCESS.2020.2977846. [15] J. Morley, K. Widdicks, and M. Hazas, “Digitalisation, energy and data demand: The impact of Internet traffic on overall and peak electricity consumption,” Energy Res. Soc. Sci., vol. 38, no. January, pp. 128–137, 2018, doi: 10.1016/j.erss.2018.01.018. [16] S. B. W. Connectivity, “Cisco Small Business 500 Series Wireless Access Points Single Point Setup,” pp. 1–8, 2013. [17] NETGEAR, “NETGEAR 200 Series,” 2015. [18] “Intel Xeon Processor E5-2420 (15M Cache, 1.90 GHz, 7.20 GT/s Intel QPI) Product SpecificationsIntel Xeon Processor E5-2420 (15M Cache, 1.90 GHz, 7.20 GT/s Intel QPI) Product Specifications,” 2019. https://ark.intel.com/content/www/us/en/ark/products/64617/i ntel-xeon- processor-e5-2420-15m-cache-1-90-ghz-7-20-gts-intel-qpi.html (accessed Oct. 26, 2019). [19] “Intel Xeon Processor E5-2680 (20MCache, 2.70 GHz, 8.00 GT/s Intel QPI) Product Specifications.,” 2019. https://ark.intel.com/content/www/us/en/ark/products/64583/i ntel- xeon-processor-e5-2680-20m-cache-2-70-ghz-8-00-gts-intel-qpi. html (accessed Oct. 26, 2019). [20] “Tensor Cores in NVIDIA Volta Architecture | NVIDIA. Accessed: Oct. 16, 2019. [Online]. Available: https://www.nvidia.com/en-gb/data- center/tensorcore/,” 2019. https://www.nvidia.com/en-gb/data- center/tensorcore/ (accessed Oct. 16, 2019).
Treść płatna
Jeśli masz wykupiony/przyznany dostęp -
zaloguj się
.
Skorzystaj z naszych propozycji zakupu!
Publikacja
PRZEGLĄD ELEKTROTECHNICZNY- e-publikacja (pdf) z zeszytu 2023-9 , nr katalogowy 145247
licencja: Osobista
Produkt cyfrowy
Nowość
10.00 zł
Do koszyka
Zeszyt
PRZEGLĄD ELEKTROTECHNICZNY- e-zeszyt (pdf) 2023-9
licencja: Osobista
Produkt cyfrowy
Nowość
70.00 zł
Do koszyka
Prenumerata
PRZEGLĄD ELEKTROTECHNICZNY - prenumerata cyfrowa
licencja: Osobista
Produkt cyfrowy
Nowość
762.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS (Prenumerata papierowa + dostęp do portalu sigma-not.pl + e-prenumerata)
1002.00 zł brutto
927.78 zł netto
74.22 zł VAT
(stawka VAT 8%)
1002.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna + wysyłka
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna
960.00 zł brutto
888.89 zł netto
71.11 zł VAT
(stawka VAT 8%)
PRZEGLĄD ELEKTROTECHNICZNY - pakowanie i wysyłka
42.00 zł brutto
34.15 zł netto
7.85 zł VAT
(stawka VAT 23%)
1002.00 zł
Do koszyka
Zeszyt
2023-9
Czasopisma
ATEST - OCHRONA PRACY
AURA
AUTO MOTO SERWIS
CHEMIK
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
ODZIEŻ
OPAKOWANIE
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH