Czasopisma
Czasopisma
Czasopisma
ATEST - OCHRONA PRACY
ATEST - OCHRONA PRACY
AURA
AURA
AUTO MOTO SERWIS
AUTO MOTO SERWIS
CHEMIK
CHEMIK
CHŁODNICTWO
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
Czasopisma
Czasopisma
Czasopisma
GAZETA CUKROWNICZA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
OCHRONA PRZED KOROZJĄ
Czasopisma
Czasopisma
Czasopisma
ODZIEŻ
ODZIEŻ
OPAKOWANIE
OPAKOWANIE
PACKAGING REVIEW
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PAPIERNICZY
Czasopisma
Czasopisma
Czasopisma
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH
WOKÓŁ PŁYTEK CERAMICZNYCH
Menu
Menu
Menu
Prenumerata
Prenumerata
Publikacje
Publikacje
Drukarnia
Drukarnia
Kolportaż
Kolportaż
Reklama
Reklama
O nas
O nas
ui-button
Twój Koszyk
Twój koszyk jest pusty.
Niezalogowany
Niezalogowany
Zaloguj się
Zarejestruj się
Reset hasła
Czasopismo
|
PRZEGLĄD ELEKTROTECHNICZNY
|
Rocznik 2021 - zeszyt 2
Application of the integrated AE and HFCT sensors for online Dry-type Transformer Partial Discharge Monitoring. Case study
10.15199/48.2021.02.24
Kitimasak TIKAKOSOL
Tanes TANITTEERAPAN
and Narong MUNGKUNG
nr katalogowy: 130188
10.15199/48.2021.02.24
Streszczenie
This study proposes a measurement technique to identify and determine the occurrence of partial discharge in the insulation of Dry-type transformers, as well as their criteria level. Concerning IEC 62478, the four AE (acoustic emission) sensors were used to determine the PD sources and one HFCT (High-Frequency Current Transducer) technique was to identify the PD source and the criteria level. This process accurately identified the PD source location occurring at any position in a transformer. The gap time was 3.2 ms. The level of partial discharge for this case study is Major PD that means soon monitoring every 3 months. The results of this technique could prevent insulation failure of a transformer in time.
Abstract
Zaprezentowano technikę wykrywania wyładowań niezupełnych w izolacji suchego transformatora. Zgodnie z IEC 62478 użyto czterech czujników emisji akustycznej AE oraz jednego czujnika prądów wysokiej częstotliwości HFCT. Umożliwia to lokalizację źródła wyładowania. (Wykorzystanie scalonego czujnika AE I HFCT do online monitoringu wyładowań niezupełnych w suchym transformatorze)
Słowa kluczowe
Partial discharge
High frequency current transducer
Dry-type transformer
Acoustic emission sensor.
Keywords
wyładowania niezupełne
izolacja suchego transformatora
czujnik AE
czujnik HFCT
Bibliografia
[1] Rutgers, W.R.; Fu, Y.H. UHF PD-Detection in a power transformer. In Proceedings of 10th International Symposium on High Voltage Engineering, Montreal, Canada, 1997; pp. 219–222. [2] Judd, M.D.; Li, Y.; Hunter, I. Partial discharge monitoring for power transformers using uhf sensors part I: sensors and signal interpretation. IEEE Electr. Insul. Mag. 2005, 21, 5–14. [3] Aschenbrenner, D.; Kranz, H.G. On line PD measurements and diagnosis on power transformers. IEEE Trans. Dielectr. Electr. Insul. 2005, 12, 206–222. [4] Kreuger, F.H., 1964, Partial Discharge Detection in High Voltage Equipment, Butterworths, English. [5] Boggs, S.A., 1990, Partial Discharge-Part III: Cavity Induced PD in Solid Dielectrics, IEEE Electr. Insul. Mag., Vol. 6, No. 1, Jan./Feb., pp. 11-20. [6] Ogihara, H., 1964, “Detection and location of Coronas in oil Immersed Transformer with Corona Detector” Electr. Eng. Jpn., Vol. 84, 1964, pp. 12-22. [7] Kuffel, J., 2012, IEC 62478/Ed1: High Voltage Test Techniques - Measurement of Partial Discharges by Electromagnetic and Acoustic Methods" Proposed Horizontal Standard”, IEC The International Electrotechnical Commission, 17 August 2012, Geneva, Switzerland. [8] Harold, R.T., 1985, “Acoustical Technology Applications in Electrical Insulation and Dielectrics”, IEEE Trans. Electr. Insul., Vol. 20, No. EI-1, Feb. 1985, pp. 1-3. [9] Varlow, B.R., Auckland, D.W. & Smith, C.D., 1999, “Acoustic Emission Analysis of High Voltage Insulation”, IEE Proc.-Sci. Meas. Technol., Vol. 146, No. 5. [10] IEC Committee, 2000, IEC 60270 High-voltage test techniques – Partial discharge measurements, IEC The International Electrotechnical Commission, December 2000, Geneva, Switzerland. [11]Transformer Committee, 2007, IEEE Std C57.127-2007 IEEE Guide for the Detection and Location of Acoustic Emissions from Partial Discharges in Oil-Immersed Power Transformers and Reactors, The Institute of Electrical and Electronics Engineers, 31 August 2007, New York, USA. [12]Urairat Fuangsoongnern, Winai Plueksawan, & Promsak Apiratikul, 2008, “Partial Discharge Analysis for Power Distribution Transformer Model”, The Proceeding of 46th Kasetsart University Annual Conference, 29 January – 1 February 2008, pp. 72-80. [13]Plueksawan, W., Apiratikul, P. & Fuangsoongnern, U., 2008, “Partial Discharge Analysis for Power Distribution Transformer Model”, EECON-31. 31st Electrical Engineering Conference, 29-31October 2008, pp. 299-302. [14]Santosh Kumar, A., Gupta, R.P., Udayakumar, K. & Venkatasami, A., 2008, “Online Partial Discharge Detection and Location Techniques for Condition Monitoring of Power Transformers: A Review”, IEEE International Conference on Condition Monitoring and Diagnosis, 21-24 April 2008, Beijing, China. [15] R.K.K. Gupta, and R.A. Jaswal, “Partial Discharge Test in Power Transformer Against Winding Insulation: A Review,” International Journal of Applied Engineering Research, Vol. 9, Number 9, pp. 1087 –1090, 2014. [16] Li JISHENG, Luo YONGFEN1, Li JUNHAO, Li YANMING, “The study of phased-ultrasonic receiving-planar array transducer for PD location in power transformer,” PRZEGLĄD ELEKTROTECHNICZNY (Electrical Review), ISSN 0033-2097, R. 87 NR 3/2011, pp.324-328. [17] Xiaoli ZHOU, Yong QIAN2, Muqing LIU, “The Application of Partial Discharge Detection for the condition assessment of XLPE Power Cables,” PRZEGLĄD ELEKTROTECHNICZNY (Electrical Review), ISSN 0033-2097, R. 88 NR 6/2012,pp.313- 316. [18]Azevedo, C.H.B; Marques, A.P. and Ribeiro, C.J., Methodology for the detection of partial discharges in power transformers using the acoustic method,” in Proc. EUROCON 2009 Conference, Saint Petersburg, Russia, May, 2009. [19]A. P. Engelbrecht, Computational Intelligence – An Introduction, 2ª ed.,John Wiley & Sons, 2007. [20] H.P. Romualdo, P.H.S. Palhares, L.C. Brito, C.J. Ribeiro, A.P. Marques; C.H.B. Azevedo, J.A.L. Santos, “Identification, Measurement and Three-dimensional Localization of partial discharges in power transformers based on Acoustic Emission Tests," In: 5th Brazilian Symposium on Electrical Systems - SBSE 2014, Foz do Iguaçu - PR, Brazil, v. 1, p. 1-6, 2014. [21] A.P. Marques, C.J. Ribeiro, C.H.B. Azevedo, L. C. Brito, J.A.L. Santos; M.A.S. Carvalho, e R.B. Nascimento, “Analysis of the implementation of an intelligent classification system of partial discharges in power transformers," In: 23rd National Seminar on Electricity Production and Transmission (SNPTEE 2015)], Foz do Iguaçu - PR, Brazil, 2015.
Treść płatna
Jeśli masz wykupiony/przyznany dostęp -
zaloguj się
.
Skorzystaj z naszych propozycji zakupu!
Publikacja
PRZEGLĄD ELEKTROTECHNICZNY- e-publikacja (pdf) z zeszytu 2021-2 , nr katalogowy 130188
licencja: Osobista
Produkt cyfrowy
Nowość
10.00 zł
Do koszyka
Zeszyt
PRZEGLĄD ELEKTROTECHNICZNY- e-zeszyt (pdf) 2021-2
licencja: Osobista
Produkt cyfrowy
Nowość
58.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY- e-zeszyt (pdf) 2021-2
licencja: Osobista
Produkt cyfrowy
Nowość
58.00 zł
Do koszyka
Prenumerata
PRZEGLĄD ELEKTROTECHNICZNY - prenumerata cyfrowa
licencja: Osobista
Produkt cyfrowy
Nowość
762.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS (Prenumerata papierowa + dostęp do portalu sigma-not.pl + e-prenumerata)
1002.00 zł brutto
927.78 zł netto
74.22 zł VAT
(stawka VAT 8%)
1002.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna + wysyłka
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna
960.00 zł brutto
888.89 zł netto
71.11 zł VAT
(stawka VAT 8%)
PRZEGLĄD ELEKTROTECHNICZNY - pakowanie i wysyłka
42.00 zł brutto
34.15 zł netto
7.85 zł VAT
(stawka VAT 23%)
1002.00 zł
Do koszyka
Zeszyt
2021-2
Czasopisma
ATEST - OCHRONA PRACY
AURA
AUTO MOTO SERWIS
CHEMIK
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
ODZIEŻ
OPAKOWANIE
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH