Czasopisma
Czasopisma
Czasopisma
ATEST - OCHRONA PRACY
ATEST - OCHRONA PRACY
AURA
AURA
AUTO MOTO SERWIS
AUTO MOTO SERWIS
CHEMIK
CHEMIK
CHŁODNICTWO
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
Czasopisma
Czasopisma
Czasopisma
GAZETA CUKROWNICZA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
OCHRONA PRZED KOROZJĄ
Czasopisma
Czasopisma
Czasopisma
ODZIEŻ
ODZIEŻ
OPAKOWANIE
OPAKOWANIE
PACKAGING REVIEW
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PAPIERNICZY
Czasopisma
Czasopisma
Czasopisma
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH
WOKÓŁ PŁYTEK CERAMICZNYCH
Menu
Menu
Menu
Prenumerata
Prenumerata
Publikacje
Publikacje
Drukarnia
Drukarnia
Kolportaż
Kolportaż
Reklama
Reklama
O nas
O nas
ui-button
Twój Koszyk
Twój koszyk jest pusty.
Niezalogowany
Niezalogowany
Zaloguj się
Zarejestruj się
Reset hasła
Czasopismo
|
PRZEGLĄD ELEKTROTECHNICZNY
|
Rocznik 2020 - zeszyt 3
Planning of the experiment for the defining of the technical state of the transformer by using amplitude-frequency characteristic
Planowanie eksperymentu przy określaniu stanu technicznego transformatora mocy
10.15199/48.2020.03.27
Oleksander RUBANENKO
Maksim GRISHCHUK
Olena RUBANENKO
nr katalogowy: 125245
10.15199/48.2020.03.27
Streszczenie
The article analyzes existing methods of diagnosing power transformers (PTs). The technique of experiment planning using D-optimal plans is investigated. According to the results of the study, a D-optimal plan of the frequency response measurements was created, which defines the algorithm of the studies. On the example of PT type TMG 1000/10 it is determined that 13 measurements are required to evaluate the condition of the PT during the interpretation of the results of the frequency response measurements. The method of determining the average frequency characteristic of PT is given. This amplitude-frequency characteristic can be used to check the PT status and to detect damage at an early stage of their development.
Abstract
Artykuł analizuje istniejące metody diagnozowania transformatorów mocy (TM). Badana jest technika planowania eksperymentu z wykorzystaniem planów optymalnych. Zgodnie z wynikami badań opracowano optymalny D-plan pomiarów odpowiedzi częstotliwościowej, który określa algorytm badań. Na przykładzie TM typu TMG 1000/10 ustalono, że do oceny stanu TM podczas interpretacji wyników pomiarów odpowiedzi częstotliwościowej potrzeba 13 pomiarów. Podano metodę wyznaczania charakterystyki średniej częstotliwości TM. Ta charakterystyka amplitudowo-częstotliwościowa może być używana do sprawdzania stanu TM i wykrywania uszkodzeń na wczesnym etapie ich rozwoju.
Słowa kluczowe
diagnosis
faults
power transformer
frequency analysis
windings.
Keywords
diagnostyka
awarie
transformator mocy
analiza częstotliwości
uzwojenia.
Bibliografia
[1] Rubanenko, O E, et al. Rationale of the optimal quantity of the examination for determination of action of the power transformer during it's discontinuation with the purpose of diagnosis. Collection of scientific works. Kharkiv: Madrid Printing House, 2018. 102 p. (2018): 43. [2] Sectoral guidance document. Testing norms for electrical equipment [Text]: Approved and enforced by the order of the Ministry of Fuel and Energy: State standard of Ukraine, 2007. - 262 p. [3] Sebok, M., Kucera, M., Korenciak, D., & Gutten, M. (2019). Thermal diagnostic systems and their application for analysis of transformer winding. Diagnostyka, 20(2), 49-55. [4] Islam, A., Khan, S. I., & Hoque, A. (2011). Detection of mechanical deformation in old aged power transformer using cross correlation co-efficient analysis method. Energy and Power engineering, 3(04), 585. [5] Miyazaki, S., Tahir, M., & Tenbohlen, S. (2019). Detection and quantitative diagnosis of axial displacement of transformer winding by frequency response analysis. IET Generation, Transmission & Distribution, 13(15), 3493-3500. [6] Shintemirov, A., Tang, W. H., & Wu, Q. H. (2010). Transformer winding condition assessment using frequency response analysis and evidential reasoning. IET Electric Power Applications, 4(3), 198-212. [7] Yao, C., Zhao, Z., Chen, Y., Zhao, X., Li, Z., Wang, Y., ... & Wei, G. (2014). Transformer winding deformation diagnostic system using online high frequency signal injection by capacitive coupling. IEEE Transactions on Dielectrics and Electrical Insulation, 21(4), 1486-1492. [8] Rahimpour, E., & Tenbohlen, S. (2010). Experimental and theoretical investigation of disc space variation in real highvoltage windings using transfer function method. (Tenbohlen, S., et al. "Zuverlässigkeits bewertung von leistungs transformatoren." inglês) IET electric power applications, 4(6), 451-461, Proc. Stuttgarter Hochspannungssymposium (2012).) [9] Contin, Alfredo, et al. "Frequency-response analysis of power transformers by means of fuzzy tools." IEEE Transactions on Dielectrics and Electrical Insulation 18.3 (2011): 900-909. [10] Abeywickrama, N., Serdyuk, Y. V., & Gubanski, S. M. (2008). Effect of core magnetization on frequency response analysis (FRA) of power transformers. IEEE Transactions on Power delivery, 23(3), 1432-1438. [11] S. A. Ryder, "Methods for comparing frequency response analysis measurements," in Proceedings of International Symposium on Electrical Insulation, Boston, MA, 2003, pp. 187-190. [12] M. Wang, A. J. Vandermaar, and K. D. Srivastava, "Improved detection of power transformer winding movement by extending the FRA high frequency range," IEEE Transactions on Power Delivery, vol. 20, pp. 1930-1938, 2005. [13] Bardyk, E.I., Kosterev, M.V.; Bolototnyy, M.P. Probabilisticstatistical modeling of the EES for estimation of the risk of failure of the power transformer for short circuit in the electrical network. Bulletin of Vinnitsa Polytechnic Institute, 2016, 2: 106- 110. [14] Lezhnyuk P. D., Rubanenko O. E., Lukyanenko Y. V., Fundamentals of Experimental Planning Theory. Laboratory Workshop - Vinnitsa: VNTU, 2005.-167 p. [15] Rubanenko E. O., Komar V. O., Petrushenko O. Y., Smolarz A., Smailova S., Imanbekova U. Determination of similarity criteria in optimization tasks by means of neuro-fuzzy modelling. Przegląd Elektrotechniczny. 2017. R. 93, nr 3. P. 93 - 96. DOI 10.15199/48.2017.03.22 [16] P. Lezhniuk, S. Kravchuk, O. Buslavets. Selfoptimization Modes of Electric Grids with Renewable Energy Sources Using the Principle of Least Action // 2019 IEEE 6th International Conferenceon Energy Smart Systems (ESS). 2019. DOI: 10.1109/ESS.2019.8764181 [17] Petro D. Lezhniuk, Mykola M. Cheremisin, Veronika V. Cherkashyna. Substantiation of Parametric Series of Overhead Lines Wire Cross-Sections in Conditions Market and Insufficient Initial Information // Przeglad Elektrotechniczny, vol 2017, №3. - pp. 103-106. [18] Petro D. Lezhniuk, Iryna O. Gunko, Sergiy V. Kravchuk. The Influence of Distributed Power Sources on Active Power Loss in the Microgrid // Przeglad Elektrotechniczny, vol 2017, №3. - pp. 107-112
Treść płatna
Jeśli masz wykupiony/przyznany dostęp -
zaloguj się
.
Skorzystaj z naszych propozycji zakupu!
Publikacja
e-Publikacja (format pdf) - nr 125245 "Planning of the experimen..."
licencja: Osobista
Produkt cyfrowy
10.00 zł
Do koszyka
Zeszyt
PRZEGLĄD ELEKTROTECHNICZNY - e-zeszyt (pdf) 2020-3
licencja: Osobista
Produkt cyfrowy
55.00 zł
Do koszyka
Prenumerata
PRZEGLĄD ELEKTROTECHNICZNY - prenumerata cyfrowa
licencja: Osobista
Produkt cyfrowy
Nowość
762.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS (Prenumerata papierowa + dostęp do portalu sigma-not.pl + e-prenumerata)
1002.00 zł brutto
927.78 zł netto
74.22 zł VAT
(stawka VAT 8%)
1002.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna + wysyłka
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna
960.00 zł brutto
888.89 zł netto
71.11 zł VAT
(stawka VAT 8%)
PRZEGLĄD ELEKTROTECHNICZNY - pakowanie i wysyłka
42.00 zł brutto
34.15 zł netto
7.85 zł VAT
(stawka VAT 23%)
1002.00 zł
Do koszyka
Zeszyt
2020-3
Czasopisma
ATEST - OCHRONA PRACY
AURA
AUTO MOTO SERWIS
CHEMIK
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
ODZIEŻ
OPAKOWANIE
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH