Czasopisma
Czasopisma
Czasopisma
ATEST - OCHRONA PRACY
ATEST - OCHRONA PRACY
AURA
AURA
AUTO MOTO SERWIS
AUTO MOTO SERWIS
CHEMIK
CHEMIK
CHŁODNICTWO
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
Czasopisma
Czasopisma
Czasopisma
GAZETA CUKROWNICZA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
OCHRONA PRZED KOROZJĄ
Czasopisma
Czasopisma
Czasopisma
ODZIEŻ
ODZIEŻ
OPAKOWANIE
OPAKOWANIE
PACKAGING REVIEW
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PAPIERNICZY
Czasopisma
Czasopisma
Czasopisma
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH
WOKÓŁ PŁYTEK CERAMICZNYCH
Menu
Menu
Menu
Prenumerata
Prenumerata
Publikacje
Publikacje
Drukarnia
Drukarnia
Kolportaż
Kolportaż
Reklama
Reklama
O nas
O nas
ui-button
Twój Koszyk
Twój koszyk jest pusty.
Niezalogowany
Niezalogowany
Zaloguj się
Zarejestruj się
Reset hasła
Czasopismo
|
PRZEGLĄD ELEKTROTECHNICZNY
|
Rocznik 2020 - zeszyt 1
Analysis of artefacts in EEG signal registered during anti-G straining maneuvers
Analiza artefaktów w sygnale EEG zarejestrowanym w trakcie wykonywania manewru przeciw-przeciążeniowego
10.15199/48.2020.01.27
Marcin KOŁODZIEJ
Krzysztof KOWALCZUK
Andrzej MAJKOWSKI
aweł TARNOWSKI
Stefan GAŹDZIŃSKI
Remigiusz Jan RAK
nr katalogowy: 124187
10.15199/48.2020.01.27
Streszczenie
An anti-G straining maneuver (AGSM) is an essential element of training pilots of high-maneuver aircrafts. Electroencephalographic signal (EEG) registered during such maneuvers could be used to detect cerebral ischemia. AGSM involves complicated physical tasks, from stretching certain parts of muscles through adequate breathing. This results in the creation of extremely large muscle artefacts, which significantly disrupt the recorded EEG signals. The presented research concerned EEG signals, recorded during individual AGSM phases, inside an overload centrifuge. The largest artefacts in the EEG band (0.5-300Hz) were observed for the electrodes Fp1, F9, FT9 and EMG1 located on cheek. The signal from the Cz and Pz electrodes appeared to be the least disturbed.
Abstract
Manewr przeciw-przeciążeniowy (AGSM) jest niezbędnym elementem szkolenia pilotów samolotów wysokomanewrowych. Sygnał elektroencefalograficzny (EEG) zarejestrowany podczas tych manewrów mógłby posłużyć do wykrycia niedokrwienia mózgu. Manewr przeciwprzeciążeniowy, obejmuje skomplikowane zadania fizyczne, od napinania pewnych partii mięśni, poprzez odpowiednie oddychanie. Powoduje to powstanie ekstremalnie dużych artefaktów odmięśniowych, które zakłócają, w sposób znaczący, rejestrowane sygnały EEG. Zaprezentowane badania dotyczyły sygnałów EEG zarejestrowanych podczas wykonywania poszczególnych faz AGSM, we wnętrzu wirówki przeciążeniowej. Największe artefakty w paśmie EEG (0.5-300Hz) zaobserwowano dla elektrod Fp1, F9, FT9 oraz EMG1 ulokowanej na policzku. Najmniej zakłócony okazał się sygnał zarejestrowany z elektrod Cz i Pz.
Słowa kluczowe
anti-G straining maneuver (AGSM)
electroencephalography (EEG)
electromyography (EMG)
signal analysis
artefact correction.
Keywords
manewr przeciw-przeciążeniowy (AGSM)
elektroencefalografia (EEG)
elektromiografia (EMG)
analiza sygnałów
korekcja artefaktów.
Bibliografia
[1] Yilmaz, U., Visual Symptoms and G-LOC in the Operational Environment and During Centrifuge Training of Turkish Jet Pilots, 70, (1999), 4. [2] Sevilla, N. L., and Gardner, J. W., G-Induced Loss of Consciousness: Case-Control Study of 78 G-LOCs in the F-15, F-16, and A-10, Aviation, Space, and Environmental Medicine 76, (2005). [3] Lyons, T. J., Marlowe, B. L., Michaud, V. J., and McGowan, D. J., Assessment of the anti-G straining maneuver (AGSM) skill performance and reinforcement program, Aviat Space Environ Med 68, (1997), 322-324. [4] Whinnery, J. E., and Gondek, M. R., Medical evaluation of Gsensitive aircrewmen, Aviat Space Environ Med 49, (1978), 1009-1013. [5] Lukatch, H. S., Echon, R. M., MacIver, M. B., and Werchan, P. M., G-force induced alterations in rat EEG activity: a quantitative analysis, Electroencephalography and Clinical Neurophysiology 103, (1997), 563-573. [6] Sawicki, D., Wolska, A., Roslon, P., and Ordysinski, S., New EEG Measure of the Alertness Analyzed by Emotiv EPOC in a Real Working Environment, in NEUROTECHNIX, 2016). [7] Majkowski, A., Kolodziej, M., and Rak, R. J., Implementation of selected EEG signal processing algorithms in asynchronous BCI, IEEE International Symposium on Medical Measurements and Applications Proceedings, (2012), pp. 1-3. [8] Li, Y., Zhang, T., Wang, B., and Nakamura, M., EEG and related physiological signals investigation under the condition of +Gz accelerations, ICME International Conference on Complex Medical Engineering (CME), (2012), pp. 60-65. [9] Li, Y., Zhang, T., Deng, L., and Wang, B., Acquisition technology research of EEG and related physiological signals under +Gz acceleration, Ir J Med Sci 183, (2014), 187-197. [10] Kowalczuk, K., Strojek, M., and Walerjan, P., Recording EEG Data in Human Centrifuge Conditions - Preliminary Report, PJAMBP 21, (2015). [11] Gwin, J. T., Gramann, K., Makeig, S., and Ferris, D. P., Removal of Movement Artifact From High-Density EEG Recorded During Walking and Running, Journal of Neurophysiology 103, (2010), 3526-3534. [12] Human Training Centrifuge, [Online], available at: http://www.wiml.waw.pl/?q=en/Dynamic_Flight_Simulator . [13] McFarland, D. J., McCane, L. M., David, S. V., and Wolpaw, J. R., Spatial filter selection for EEG-based communication, Electroencephalography and Clinical Neurophysiology 103, (1997), 386-394. [14] Mennes, M., Wouters, H., Vanrumste, B., Lagae, L., and Stiers, P., Validation of ICA as a tool to remove eye movement artifacts from EEG/ERP, Psychophysiology 47, (2010), 1142- 1150. [15] Winkler, I., Debener, S., Müller, K., and Tangermann, M., On the influence of high-pass filtering on ICA-based artifact reduction in EEG-ERP, 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), (2015), pp. 4101-4105.
Treść płatna
Jeśli masz wykupiony/przyznany dostęp -
zaloguj się
.
Skorzystaj z naszych propozycji zakupu!
Publikacja
e-Publikacja (format pdf) - nr 124187 "Analysis of artefacts in ..."
licencja: Osobista
Produkt cyfrowy
10.00 zł
Do koszyka
Zeszyt
PRZEGLĄD ELEKTROTECHNICZNY - e-zeszyt (pdf) 2020-1
licencja: Osobista
Produkt cyfrowy
55.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY- e-zeszyt (pdf) 2020-10
licencja: Osobista
Produkt cyfrowy
Nowość
55.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY- e-zeszyt (pdf) 2020-11
licencja: Osobista
Produkt cyfrowy
Nowość
55.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY- e-zeszyt (pdf) 2020-12
licencja: Osobista
Produkt cyfrowy
Nowość
55.00 zł
Do koszyka
Prenumerata
PRZEGLĄD ELEKTROTECHNICZNY - prenumerata cyfrowa
licencja: Osobista
Produkt cyfrowy
Nowość
762.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS (Prenumerata papierowa + dostęp do portalu sigma-not.pl + e-prenumerata)
1002.00 zł brutto
927.78 zł netto
74.22 zł VAT
(stawka VAT 8%)
1002.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna + wysyłka
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna
960.00 zł brutto
888.89 zł netto
71.11 zł VAT
(stawka VAT 8%)
PRZEGLĄD ELEKTROTECHNICZNY - pakowanie i wysyłka
42.00 zł brutto
34.15 zł netto
7.85 zł VAT
(stawka VAT 23%)
1002.00 zł
Do koszyka
Zeszyt
2020-1
Czasopisma
ATEST - OCHRONA PRACY
AURA
AUTO MOTO SERWIS
CHEMIK
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
ODZIEŻ
OPAKOWANIE
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH