Czasopisma
Czasopisma
Czasopisma
ATEST - OCHRONA PRACY
ATEST - OCHRONA PRACY
AURA
AURA
AUTO MOTO SERWIS
AUTO MOTO SERWIS
CHEMIK
CHEMIK
CHŁODNICTWO
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
Czasopisma
Czasopisma
Czasopisma
GAZETA CUKROWNICZA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
OCHRONA PRZED KOROZJĄ
Czasopisma
Czasopisma
Czasopisma
ODZIEŻ
ODZIEŻ
OPAKOWANIE
OPAKOWANIE
PACKAGING REVIEW
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PAPIERNICZY
Czasopisma
Czasopisma
Czasopisma
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH
WOKÓŁ PŁYTEK CERAMICZNYCH
Menu
Menu
Menu
Prenumerata
Prenumerata
Publikacje
Publikacje
Drukarnia
Drukarnia
Kolportaż
Kolportaż
Reklama
Reklama
O nas
O nas
ui-button
Twój Koszyk
Twój koszyk jest pusty.
Niezalogowany
Niezalogowany
Zaloguj się
Zarejestruj się
Reset hasła
Czasopismo
|
WIADOMOŚCI ELEKTROTECHNICZNE
|
Rocznik 2019 - zeszyt 9
Szybkozmienne przepięcia łączeniowe w rozdzielnicach izolowanych gazem SF6 (GIS)
Very fast transient overvoltages in gas-insulated substations during switching operations
10.15199/74.2019.9.5
Janusz Karolak
nr katalogowy: 122214
10.15199/74.2019.9.5
Streszczenie
Omówiono zagadnienia powstawania bardzo szybko zmiennych przepięć w obwodach głównych (VFTO) oraz w osłonach (TEV) rozdzielnic z izolacją gazową (GIS), występujących podczas niektórych operacji łączeniowych wykonywanych łącznikami zainstalowanymi w GIS. Na podstawie danych literaturowych oszacowano poziomy zagrożeń izolacji rozdzielnic wywołane tymi zjawiskami oraz scharakteryzowano środki stosowane przez producentów do ich ograniczania.
Abstract
In the article there are discussed the appearing of VFTO in main circuit of GIS and transient voltage in their enclosure (TEV) during some switching operations. Based on literature data it was estimated the level of threatening the GIS isolation by these phenomena and characterized countermeasure used by the producers for limiting them.
Słowa kluczowe
rozdzielnice izolowane gazem (GIS)
bardzo szybko zmienne przepięcia (VFTO)
napięcia przejściowe w osłonach (TEV)
operacje łączeniowe
Keywords
gas insulated substation (GIS)
very fast transient overvoltage (VFTO)
transient enclosure voltage (TEV)
switching operations
Bibliografia
[1] Aanestad H. 1988. Substation Earthing with Special Regard to Transient Ground Potential Rise. CIGRE, Rep. 23-06. [2] Abd Allah M.A., Said A. Badran E.A. 2014. New Techniques for Disconnector Switching VFT Mitigation in GIS. IJECE, 4(2). [3] Bang Liangeng at al. 2007. Estimation of VFTO for GIS and Hybrid-GIS of China 1000 kV pilot project and its countermeasures. IEC/CIGRE UHV Symposium, Beijing. [4] Buesch W. at al: Attenuation of Fast Transients in GIS Earting Systems. CIGRE 1988, Rep. 23-10. [5] Cai Y., Guan Y., Liu W. 2015. Measurement of transient enclosure voltage in 220 kV gas insulated substation. IEEE IIMTC, Pisa, Italy. [6] CIGRE Brochure 35, WG 33/13-09: Monograph on GIS Very Fast Transients. July 1989. [7] CIGRE Brochure 456, WG A3.22: Background of Technical Specifications for Substation Equipment exceeding 800 kV AC. April 2011. [8] CIGRE 1988. Sesion Group 23, Discussion of Preferential Subject 2: Grounding and Earthing in Substation. (Nitta T.) [9] Duan S. 2015. Measurement and modeling of Very Fast Transient Current in 220 kV GIS. Vacuum, 120. [10] Himasaila V. at al. 2017. Review on Analysis of Very Fast Transient Overvotage in Gas insulated Substation. IJSRET, 6(7). [11] IEC 62271-102: High-voltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches. [12] IEC 62271-203: High-voltage switchgear and controlgear - Part 203: Gas - insulated metal-enclosed switchgear for rated voltages above 52 kV. [13] IEC 62271-209: High-voltage switchgear and controlgear - Part 209: Cable connection for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV. [14] IEC 62271-211: High-voltage switchgear and controlgear - Part 211: Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages above 52 kV. [15] Kho D.T.A., Smith K.S. 2011. Analysis of Very Fast Transients Overvoltages in a proposed 275 Gas Insulated Substation. International Conference on Power System Transients, Delft. [16] Kuczek T., Florkowski M. 2011. Analysis of Transient Overvoltages in High Voltage Gas Insulated Substation. XXI Sem. "Zastosowanie Komputerów w nauce i Technice", 2011, PTETiS, Ref 16. [17] Kumar A., Mishra M.K. 2008. VFT Study for EHV-GIS Substation. Fifteen National Power System Conference (NPSC), Bombay. [18] Noack F. at al. 1988. Fast Transient in the Earthing System of GIS. CIGRE, Rep. 33-06. [19] Pathak N., Bhatti T.S., Ibraheem. 2015. Study of Very Transient Overvoltages and Mitigation Techniques of Gas Insulated Substation. ICCPTC. [20] Rao M.M., Thomas M.J., Singh B.P. 2005. Frequency Characteristics of Very Fast Transient Currents in a 245 kV GIS. IEEE TPD, 20(4). [21] Report of WG 33/13-09: Very Fast Transient Phenomena Associated with Gas Insulated Substation. CIGRE 1988, Rep. 33-13. [22] Riechert U. at al: Very Fast Transient overvoltages during switching of bus-charging currents by 1100 kV disconnector. CIGRE 2010, Rep. A3-107. [23] Said A. Badran E.A, Abd Allah M.A. 2012. Mitigation of Very Fast Transient Overvoltages at the More Sensitive Points in Gas-Insulated Substation. IJEEI, 4(3). [24] Sao S., Rao D.: Effect of Very Fast Transient overvoltages at high frequency in Gas Insulated Substation during switching operations. IJSRP, 3(3). [25] Szewczyk M. at al. 2012. Measurement and Simulations of Very Fast Transients during Disconnector Type Testing in UHV Gas-Insulated Switchgear. Przegląd Elektrotechniczny, 88 (11b). [26] Weijiang Chen at al: Experimental and Simulation Research on VFTO in UHV GIS. CIGRE 2014, Rep. A3-102
Treść płatna
Jeśli masz wykupiony/przyznany dostęp -
zaloguj się
.
Skorzystaj z naszych propozycji zakupu!
Publikacja
e-Publikacja (format pdf) - nr 122214 "Szybkozmienne przepięcia ..."
licencja: Osobista
Produkt cyfrowy
10.00 zł
Do koszyka
Zeszyt
WIADOMOŚCI ELEKTROTECHNICZNE - e-zeszyt (pdf) 2019-9
licencja: Osobista
Produkt cyfrowy
33.00 zł
Do koszyka
Prenumerata
WIADOMOŚCI ELEKTROTECHNICZNE - prenumerata cyfrowa
licencja: Osobista
Produkt cyfrowy
Nowość
402.00 zł
Do koszyka
WIADOMOŚCI ELEKTROTECHNICZNE - papierowa prenumerata roczna + wysyłka
licencja: Osobista
Szczegóły pakietu
Nazwa
WIADOMOŚCI ELEKTROTECHNICZNE - papierowa prenumerata roczna
492.00 zł brutto
455.56 zł netto
36.44 zł VAT
(stawka VAT 8%)
WIADOMOŚCI ELEKTROTECHNICZNE - pakowanie i wysyłka
42.00 zł brutto
34.15 zł netto
7.85 zł VAT
(stawka VAT 23%)
534.00 zł
Do koszyka
WIADOMOŚCI ELEKTROTECHNICZNE - PAKIET prenumerata PLUS
licencja: Osobista
Szczegóły pakietu
Nazwa
WIADOMOŚCI ELEKTROTECHNICZNE - PAKIET prenumerata PLUS (Prenumerata papierowa + dostęp do portalu sigma-not.pl + e-prenumerata)
600.00 zł brutto
555.56 zł netto
44.44 zł VAT
(stawka VAT 8%)
600.00 zł
Do koszyka
Zeszyt
2019-9
Czasopisma
ATEST - OCHRONA PRACY
AURA
AUTO MOTO SERWIS
CHEMIK
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
ODZIEŻ
OPAKOWANIE
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH