Czasopisma
Czasopisma
Czasopisma
ATEST - OCHRONA PRACY
ATEST - OCHRONA PRACY
AURA
AURA
AUTO MOTO SERWIS
AUTO MOTO SERWIS
CHEMIK
CHEMIK
CHŁODNICTWO
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
Czasopisma
Czasopisma
Czasopisma
GAZETA CUKROWNICZA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
OCHRONA PRZED KOROZJĄ
Czasopisma
Czasopisma
Czasopisma
ODZIEŻ
ODZIEŻ
OPAKOWANIE
OPAKOWANIE
PACKAGING REVIEW
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PAPIERNICZY
Czasopisma
Czasopisma
Czasopisma
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH
WOKÓŁ PŁYTEK CERAMICZNYCH
Menu
Menu
Menu
Prenumerata
Prenumerata
Publikacje
Publikacje
Drukarnia
Drukarnia
Kolportaż
Kolportaż
Reklama
Reklama
O nas
O nas
ui-button
Twój Koszyk
Twój koszyk jest pusty.
Niezalogowany
Niezalogowany
Zaloguj się
Zarejestruj się
Reset hasła
Czasopismo
|
PRZEGLĄD ELEKTROTECHNICZNY
|
Rocznik 2019 - zeszyt 6
Mathematical model of XLPE insulated cable power line with underground installation
Model matematyczny kabla w izolacji XLPE przy podziemnej energetycznej linii kablowej
10.15199/48.2019.06.14
Oleg KROPOTIN
Vsevolod TKACHENKO
Aleksandr SHEPELEV
Elena PETROVA
Vladimir GORYUNOV
Aleksandr BIGUN
nr katalogowy: 120458
10.15199/48.2019.06.14
Streszczenie
This paper presents mathematical modeling of a stationary thermal field in the cross section of a single-conductor cable with XLPE insulation. The equivalent circuit of thermal processes is made using the method of homogeneous bodies, and it includes dielectric losses, takes into account the ambient temperature, as well as the temperature dependence of the active resistance of the cable core. The assessment of the mathematical model adequacy is performed by comparing the obtained results with the calculation of thermal and electrical processes using the finite element method implemented in the software «ANSYS Workbench». The resulting mathematical model can be used to control the capacity of cable lines with XLPE insulation and limit their service life due to temperature aging of the insulation.
Abstract
Przedstawiono matematyczne modelowanie stacjonarnego pola temperatur w przekroju kabla z izolacją xlpe. Schemat procesów termicznych wykonano metodą jednorodnych ciał i obejmuje on straty dielektryczne biorąc pod uwagę temperaturę otoczenia, a także zależność od temperatury rezystancji żyły kablowej. Ocena adekwatności modelu matematycznego odbywa się poprzez porównanie uzyskanych wyników z obliczeń cieplnych i elektrycznych procesów z wykorzystaniem metody elementów skończonych, realizowanego w programie „ANSYS Workbench". Otrzymany model matematyczny może być używany do kontroli przepustowości linii kablowych z izolacją xlpe i ograniczenia ich żywotności poprzez temperatury starzenia się izolacji.
Słowa kluczowe
XLPE insulation cable
equivalent circuit
thermal resistance.
Keywords
Kabel o izolacji XLPE
ekwiwalent schemat
opór cieplny.
Bibliografia
[1] S.S. Girshin, A. A. Bubenchikov, T. V. Bubenchikova, V. N. Goryunov and D. S. Osipov, "Mathematical model of electric energy losses calculating in crosslinked four-wire polyethylene insulated (XLPE) aerial bundled cables," 2016 ELEKTRO, Strbske Pleso, 2016, pp. 294-298. DOI: 10.1109/ELEKTRO.2016.7512084. [2] Henryk Kocot, Paweł Kubek Analiza poprzecznego rozkładu temperatury w przewodach elektroenergetycznych // Przeglad Elektrotechniczny. 2017. No. 10. P. 132-135. DOI: 10.15199/48.2017.10.31. [3] Girshin, S.S., Bigun, A.A.Y., Ivanova, E.V., Petrova, E.V., Goryunov, V.N., Shepelev, A.O. The grid element temperature considering when selecting measures to reduce energy losses on the example of reactive power compensation // Przeglad Elektrotechniczny. 2018. No. 8. P. 101-104. DOI 10.15199/48.2018.08.24. [4] Goryunov V.N., Girshin S.S., Kuznetsov E.A. [and etc.] A mathematical model of steady-state thermal regime of insulated overhead line conductors // EEEIC 2016 - International Conference on Environment and Electrical Engineering 16. 2016. С. 7555481. [5] Kukharchuk I. B., Kazakov A. V., Trufanova N. M. Investigation of heating of 150 kV underground cable line for various conditions of laying // Materials Science and Engineering. 2018. No. 327. P. 1-6. DOI 10.1088/1757-899X/327/2/022041. 80 PRZEGLĄD ELEKTROTECHNICZNY, ISSN 0033-2097, R. 95 NR 6/2019 [6] Lobão J. A., Devezas T., Catalão JPS. Reduction of greenhouse gas emissions resulting from decreased losses in the conductors of an electrical installation // Energy Convers Manage. 2014. Vol. 87. P. 787-95. DOI: 10.1016/j.enconman.2014.07.067. [7] Tian Q, Lin X. Winding capacitance dividing scheme for a highvoltage cable-wound generator // Energy Convers Manage. 2010. Vol. 51. P. 428-33. DOI: 10.1016/j.enconman.2009.10.004. [8] Hwang C. C., Jiang Y. H. Extensions to the finite element method for thermal analysis of underground cable systems // Electric Power Systems Research. 2003. Vol. 64 (2). P. 159- 164. DOI: 10.1016/S0378-7796(02)00192-X. [9] Al-Saud M. S., El-Kady M. A., Findlay R. D. A new approach to underground cable performance assessment // Electric Power Systems Research. 2008. Vol. 78 (5). P. 907-18. DOI: 10.1016/j.epsr.2007.06.010. [10] De Lieto V. R., Fontana L., Vallati A. Thermal analysis of underground electrical power cables buried in nonhomogeneous soils // Applied Thermal Engineering. 2011. Vol. 31. P. 772-778. [11] De Lieto V. R., Fontana L., Vallati A. Experimental study of the thermal field deriving from an underground electrical power cable buried in nonhomogeneous soils // Applied Thermal Engineering. 2014. Vol. 62 (2). P. 390-397. DOI: 10.1016/j.applthermaleng.2013.09.002. [12] Papagiannopoulos I., Chatziathanasiou V., Exizidis L. [et al.]. Behaviour of the thermal impedance of buried power cables // International Journal of Electrical Power & Energy Systems. 2013. Vol. 44 (1). P. 383-387. DOI: 10.1016/j.ijepes.2012.07.064. [13] Chatziathanasiou V., Chatzipanagiotou P., Papagiannopoulos I. [et al.]. Dynamic thermal analysis of underground medium power cables using thermal impedance, time constant distribution and structure function // Applied Thermal Engineering. 2013. Vol. 60. P. 256-260. [14] Wiecek B., De Mey G., Chatziathanasiou V. [et al.]. Theodosoglou I. Harmonic analysis of dynamic thermal problems in high voltage overhead transmission lines and buried cables // International Journal of Electrical Power & Energy Systems. 2014. Vol. 58. P. 199-205. [15] G. Coletta, G. V. Persiano, A. Vaccaro and D. Villacci, "Enabling technologies for distributed temperature monitoring of smart power cables," 2018 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems (EESMS), Salerno, 2018, pp. 1-4. DOI: 10.1109/EESMS.2018.8405818. [16] Rasoulpoor M., Mirzaie M., Mirimani S. M. Thermal assessment of sheathed medium voltage power cables under non-sinusoidal current and daily load cycle // Applied Thermal Engineering. 2017. No. 123. P. 353-364. DOI 10.1016/j.applthermaleng.2017.05.070. [17] Łukasz Topolski, Jurij Warecki, Zbigniew Hanzelka Methods for determining power losses in cable lines with non-linear load // Przeglad Elektrotechniczny. 2018. No. 9. P. 85-90. DOI 10.15199/48.2018.09.21. [18] Yunus Bicen Trend adjusted lifetime monitoring of underground power cable // Electric Power Systems Research. 2017. No. 143. P. 189-196. DOI 10.1016/j.epsr.2016.10.045. [19] Shchebeniuk L. A., Antonets T. Yu. Investigation of losses in insulation of high-voltage cables with XLPE insulation // Electrical Engineering & Electromechanics. 2016. No. 4. P. 58- 62. DOI 10.20998/2074-272X.2016.4.08. [20] Yang Yang, Donald M. Hepburn, Chengke Zhou, Wenjun Zhou, Wei jiang, Zhi Tian On-line monitoring and analysis of the dielectric loss in cross-bonded HV cable system // Electric Power Systems Research. 2017. No. 149. P. 89-101. DOI 10.1016/j.epsr.2017.03.036.
Treść płatna
Jeśli masz wykupiony/przyznany dostęp -
zaloguj się
.
Skorzystaj z naszych propozycji zakupu!
Publikacja
e-Publikacja (format pdf) - nr 120458 "Mathematical model of XLP..."
licencja: Osobista
Produkt cyfrowy
10.00 zł
Do koszyka
Zeszyt
PRZEGLĄD ELEKTROTECHNICZNY - e-zeszyt (pdf) 2019-6
licencja: Osobista
Produkt cyfrowy
55.00 zł
Do koszyka
Prenumerata
PRZEGLĄD ELEKTROTECHNICZNY - prenumerata cyfrowa
licencja: Osobista
Produkt cyfrowy
Nowość
762.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS (Prenumerata papierowa + dostęp do portalu sigma-not.pl + e-prenumerata)
1002.00 zł brutto
927.78 zł netto
74.22 zł VAT
(stawka VAT 8%)
1002.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna + wysyłka
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna
960.00 zł brutto
888.89 zł netto
71.11 zł VAT
(stawka VAT 8%)
PRZEGLĄD ELEKTROTECHNICZNY - pakowanie i wysyłka
42.00 zł brutto
34.15 zł netto
7.85 zł VAT
(stawka VAT 23%)
1002.00 zł
Do koszyka
Zeszyt
2019-6
Czasopisma
ATEST - OCHRONA PRACY
AURA
AUTO MOTO SERWIS
CHEMIK
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
ODZIEŻ
OPAKOWANIE
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH