Czasopisma
Czasopisma
Czasopisma
ATEST - OCHRONA PRACY
ATEST - OCHRONA PRACY
AURA
AURA
AUTO MOTO SERWIS
AUTO MOTO SERWIS
CHEMIK
CHEMIK
CHŁODNICTWO
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
Czasopisma
Czasopisma
Czasopisma
GAZETA CUKROWNICZA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
OCHRONA PRZED KOROZJĄ
Czasopisma
Czasopisma
Czasopisma
ODZIEŻ
ODZIEŻ
OPAKOWANIE
OPAKOWANIE
PACKAGING REVIEW
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PAPIERNICZY
Czasopisma
Czasopisma
Czasopisma
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH
WOKÓŁ PŁYTEK CERAMICZNYCH
Menu
Menu
Menu
Prenumerata
Prenumerata
Publikacje
Publikacje
Drukarnia
Drukarnia
Kolportaż
Kolportaż
Reklama
Reklama
O nas
O nas
ui-button
Twój Koszyk
Twój koszyk jest pusty.
Niezalogowany
Niezalogowany
Zaloguj się
Zarejestruj się
Reset hasła
Czasopismo
|
OCHRONA PRZED KOROZJĄ
|
Rocznik 2017 - zeszyt 10
Badania polaryzacyjne wpływu chlorków na cynkową powłokę ochronną stali zbrojeniowej w dojrzewającym betonie
Polarization tests concerning chloride impact on protective zinc coatings applied on reinforcing steel in curing concrete
10.15199/40.2017.10.1
Jacek KOŁODZIEJ
Mariusz JAŚNIOK
nr katalogowy: 109885
10.15199/40.2017.10.1
Streszczenie
Przeprowadzono analizę wpływu chlorków na stalowe pręty zbrojeniowe zabezpieczone powłokami cynkowymi oraz porównawczo na pręty bez żadnych powłok ochronnych. Pręty zbrojeniowe badano w betonie o zawartości chlorków wynoszącej 2% masy cementu zawartego w betonie, a także w betonie referencyjnym bez chlorków. Badania polaryzacyjne realizowano w trybie potencjodynamicznym w układzie trójelektrodowym, w którym elektrodą badaną był umieszczony w betonie pręt z stali żebrowanej gatunku RB500. Badania rozpoczęto po 2 tygodniach od zabetonowania próbek, a następnie kontynuowano w odstępach jedno i dwu-tygodniowych. Wyniki badań pokazały, że w początkowym okresie dojrzewania betonu, niezależnie od występowania lub braku chlorków w betonie, na powierzchni powłoki cynkowej zachodzą dość intensywne procesy elektrochemiczne. Po osiągnięciu przez beton normowej – 28-dniowej dojrzałości, procesy elektrodowe ulegają silnemu spowolnieniu i stabilizacji.
Abstract
We analysed chloride impact on steel rebars with protective zinc coatings and compared them with rebars without any protective coatings. The rebars were tested in concrete with chloride content of 2% cement weight and in reference concrete without chlorides. Polarization tests were conducted in the potentiodynamic mode in the three-electrode system, where the working electrode was the rebar made of ribbed steel of grade RB500, placed in concrete. The tests began two weeks after placing specimens in concrete. They were continued in one- and twoweek intervals. The test results showed that at the early maturity age of concrete, quite intensive electrochemical processes took place on the zinc coat surface regardless of chloride presence. When concrete was fully matured, that is, after 28 days according to the standard, electrode processes significantly slowed down and then stabilised.
Słowa kluczowe
konstrukcje betonowe
stal zbrojeniowa
korozja
chlorki
powłoka cynkowa
pomiary potencjodynamiczne
gęstość prądu korozyjnego
Keywords
concrete structures
reinforcing steel
corrosion
chlorides
zinc coating
potentiodynamic measurements
corrosion current density
Bibliografia
[1] ASTM A123/A123M. "Standard Specifications for Zinc (Hot-Dipped Galvanized) Coatings on Iron and Steel Products". [2] ASTM A767/A767M. 2015. "Standard Specification for Zinc-Coated (Galvanized) Steel Bars for Concrete Reinforcement". [3] Baltazar-Zamora Miguel et al. 2016. "Electrochemical behaviour of galvanized steel embedded in concrete exposed to sand contaminated with NaCl". International Journal of Electrochemical Science 11 (12) : 10306-10319. [4] Barbucci Antonio, Marina Delucchi, Giacomo Cerisola. 1997. "Organic coatings for concrete protection: liquid water and water vapour permeabilities". Progress in Organic Coatings 30 (4) : 293-297. [5] Bautista A., J.A. González. 1996. "Analysis of the protective efficiency of galvanizing against corrosion of reinforcements embedded in chloride contaminated concrete". Cement and Concrete Research 26 (2) : 215-224. [6] Bellezze T., M. Malavolta, A. Quaranta, N. Ruffini, G. Roventi. 2006. "Corrosion behaviour in concrete of three differently galvanized steel bars". Cement and Concrete Composites 28 (3) : 246-255. [7] Brenna Andrea, Fabio Bolzoni, Silvia Beretta, Marco Ormellese. 2013. "Longterm chloride-induced corrosion monitoring of reinforced concrete coated with commercial polymer-modified mortar and polymeric coatings". Construction and Building Materials 48 : 734-744. [8] Darwin David, JoAnn Browning, Matthew O’Reilly, Lihua Xing. 2009. "Critical chloride corrosion threshold of galvanized reinforcing bars". ACI Materials Journal 106 (2) : 176-183. [9] Dong ShiGang, Bing Zhao, ChangJian Lin, RongGui Du, RongGang Hu, Gregory Xiaoge Zhang. 2012. "Corrosion behavior of epoxy/zinc duplex coated rebar embedded in concrete in ocean environment". Construction and Building Materials 28 (1) : 72-78. [10] Erdoğdu Sakir, Theodore Bremner, Irina Kondratova. 2001. "Accelerated testing of plain and epoxy-coated reinforcement in simulated seawater and chloride solutions". Cement and Concrete Research 31 (6) : 861-867. [11] Faustino Pedro, Ana Brás, Thomaz Ripper. 2014. "Corrosion inhibitors’ effect on design service life of RC structures". Construction and Building Materials 53 : 360-369. [12] Jaśniok Mariusz, Jacek Kołodziej. 2015. "Badania impedancyjne wpływu alkalicznego odczynu cieczy porowej betonu na cynkową powłokę ochronną stali zbrojeniowej" Roczniki Inżynierii Budowlanej 15 : 37-42. [13] Jaśniok Mariusz, Jacek. 2016. "Badania elektrochemiczne stali zbrojeniowej chronionej powłoką cynkową w kontakcie z cieczą porową betonu". Izolacje 4 : 53-55. [14] Kwiatkowski Lech. 2004. "Cynk i ochrona przed korozją". Ochrona przed Korozją 47 (10) : 256-257. [15] Liu Shuan, Huyuan Sun, Lijuan Sun, Huiji Fan. 2012. "Effects of pH and Cl - concentration on corrosion behavior of the galvanized steel in simulated rust layer solution". Corrosion Science 65 : 520-527. [16] Manning David. 1996. "Corrosion performance of epoxy-coated reinforcing steel: North American experience". Construction and Building Materials 10 (5) : 349-365. [17] Otieno Mike, Hans Beushausen, Mark Alexander. 2016. "Chloride-induced corrosion of steel in cracked concrete - Part II: Corrosion rate prediction models". Cement and Concrete Research 79 : 386-394. [18] PN-EN 1766. 2011. "Wyroby i systemy do ochrony i napraw konstrukcji betonowych - Metody badań - Betony wzorcowe do badań". [19] PN-EN 1992-1-1. 2008. "Eurokod 2. Projektowanie konstrukcji z betonu. Część 1-1: Reguły ogólne i reguły dla budynków". [20] Rus Vasile, Andreea Hegyi, Horatiu Vermessan, Ancuta Elena Tiuc. 2015. "Kinetics of the corrosion process of hot dip galvanized steel reinfocement in fresh concrete". Studia Universitatis Babes-Bolyai Chemia 2 : 409-419. [21] Szweda Zofia, Adam Zybura. 2013. "Theoretical model and experimental tests on chloride diffusion and migration processes in concrete". Procedia Engineering 57 : 1121-1130. [22] Yeomans Stephen. 2004. Galvanized Steel Reinforcement in Concrete. Oxford: Elsevier. [23] Zybura Adam, Mariusz Jaśniok, Tomasz Jaśniok. 2011. Diagnostyka konstrukcji żelbetowych. Badania korozji zbrojenia i właściwości ochronnych betonu, t. 2. Warszawa: PWN.
Treść płatna
Jeśli masz wykupiony/przyznany dostęp -
zaloguj się
.
Skorzystaj z naszych propozycji zakupu!
Publikacja
e-Publikacja (format pdf) - nr 109885 "Badania polaryzacyjne wpł..."
licencja: Osobista
Produkt cyfrowy
10.00 zł
Do koszyka
Zeszyt
OCHRONA PRZED KOROZJĄ - e-zeszyt (pdf) 2017-10
licencja: Osobista
Produkt cyfrowy
42.00 zł
Do koszyka
Prenumerata
OCHRONA PRZED KOROZJĄ - prenumerata cyfrowa
licencja: Osobista
Produkt cyfrowy
Nowość
504.00 zł
Do koszyka
OCHRONA PRZED KOROZJĄ - papierowa prenumerata roczna + wysyłka
licencja: Osobista
Szczegóły pakietu
Nazwa
OCHRONA PRZED KOROZJĄ - papierowa prenumerata roczna
636.00 zł brutto
588.89 zł netto
47.11 zł VAT
(stawka VAT 8%)
OCHRONA PRZED KOROZJĄ - pakowanie i wysyłka
42.00 zł brutto
34.15 zł netto
7.85 zł VAT
(stawka VAT 23%)
678.00 zł
Do koszyka
OCHRONA PRZED KOROZJĄ - PAKIET prenumerata PLUS
licencja: Osobista
Szczegóły pakietu
Nazwa
OCHRONA PRZED KOROZJĄ - PAKIET prenumerata PLUS (Prenumerata papierowa + dostęp do portalu sigma-not.pl + e-prenumerata)
762.00 zł brutto
705.56 zł netto
56.44 zł VAT
(stawka VAT 8%)
762.00 zł
Do koszyka
Zeszyt
2017-10
Czasopisma
ATEST - OCHRONA PRACY
AURA
AUTO MOTO SERWIS
CHEMIK
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
ODZIEŻ
OPAKOWANIE
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH