Czasopisma
Czasopisma
Czasopisma
ATEST - OCHRONA PRACY
ATEST - OCHRONA PRACY
AURA
AURA
AUTO MOTO SERWIS
AUTO MOTO SERWIS
CHEMIK
CHEMIK
CHŁODNICTWO
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
Czasopisma
Czasopisma
Czasopisma
GAZETA CUKROWNICZA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
OCHRONA PRZED KOROZJĄ
Czasopisma
Czasopisma
Czasopisma
ODZIEŻ
ODZIEŻ
OPAKOWANIE
OPAKOWANIE
PACKAGING REVIEW
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PAPIERNICZY
Czasopisma
Czasopisma
Czasopisma
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH
WOKÓŁ PŁYTEK CERAMICZNYCH
Menu
Menu
Menu
Prenumerata
Prenumerata
Publikacje
Publikacje
Drukarnia
Drukarnia
Kolportaż
Kolportaż
Reklama
Reklama
O nas
O nas
ui-button
Twój Koszyk
Twój koszyk jest pusty.
Niezalogowany
Niezalogowany
Zaloguj się
Zarejestruj się
Reset hasła
Czasopismo
|
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
|
Rocznik 2017 - zeszyt 7
Praca wodnej pompy ciepła w warunkach konwekcji wymuszonej
Heat Pump Working Under Conditions f Forced Convection of Water
10.15199/9.2017.7.6
WOJCIECH TUCHOWSKI
BOGUSŁAW ZAKRZEWSKI
nr katalogowy: 107668
10.15199/9.2017.7.6
Streszczenie
Wodne pompy ciepła są w Polsce najrzadziej stosowanymi pompami ciepła. Jest to spowodowane wysokimi kosztami inwestycyjnymi oraz skomplikowanymi uwarunkowaniami prawnymi. Cechują się one jednak wysokim współczynnikiem efektywności energetycznej w stosunku do innych rozwiązań. Prace takiego urządzenia rozpatrywać można w dwóch stanach, konwekcji swobodnej, kiedy mamy do czynienia ze zbiornikami wodnymi w których występują jedynie konwekcyjne ruchy wody spowodowane różnicą gęstości (stacjonarne zbiorniki wodne takie jak jeziora, stawy, przydomowe baseny) oraz konwekcji wymuszonej, kiedy istnieje ukierunkowany przepływ wody w zbiorniku (rzeki, morza, ścieki kanalizacyjne). Wydajność oraz efektywność energetyczna wodnej pompy ciepła w tych dwóch stanach znacznie się różni. Jak wynika z analiz teoretycznych oraz badań wstępnych przeprowadzonych na modelu wodnej pompie ciepła znajdującej się na Wydziale Techniki Morskiej i Transportu, wymuszony ruch wody na powierzchni parowacza wpływa korzystnie na charakterystyki energetyczne urządzenia. Badania wstępne w warunkach konwekcji wymuszonej prowadzone były w okresie letnim oraz zimowym, a poprzedzone zostały dokładnymi badaniami w warunkach konwekcji swobodniej w okresie całego roku. Obecnie trwają analizy oraz przygotowania do prowadzenia właściwych badań kształtowania się efektywności energetycznej wodnej pompy ciepła w warunkach konwekcji wymuszonej w okresie zimowym (w niskiej temperaturze wody, tw = 1÷4oC).
Abstract
Water source heat pumps are the least frequently used heat pumps in Poland. It follows high investment costs and the increasingly complex legal conditions. However, they are characterized by a high rate of energy efficiency compared to other solutions. The work of such a device may be viewed in two states, natural convection, when we are dealing with water reservoirs in which there are only a convective movement of water caused by different density (stationary water reservoirs such as lakes, ponds, backyard swimming pools) and forced convection, when there is a directed flow of water in the reservoir (rivers, sea, sewage drainage). Performance and energy efficiency water source heat pumps in these two states varies greatly. As follows from theoretical analysis and preliminary studies conducted on a model water source heat pump located at the Faculty of Maritime Technology and Transport, forced movement of water on the surface of the evaporator has a beneficial effect on the energy performance of the device. Preliminary studies in conditions of forced convection were conducted during the summer and winter, and were preceded by accurate research in the natural convection conditions throughout the year. Currently, analysis, and preparations are being made to conduct proper research development of the energy efficiency water source heat pump in conditions of forced convection for the winter (in the low water temperature, tw = 1÷4°C).
Słowa kluczowe
wodna pompa ciepła
konwekcja wymuszona
prędkość przepływu wody
współczynnik wnikania ciepła
ciepło krzepnięcia wody
Keywords
water source heat pump
forced Convection
water flow rate
heat transfer coefficient
heat coagulation of water
Bibliografia
[1] Bogusław Zakrzewski, Wojciech Tuchowski, Zbigniew Szkibiel. 2011. "Badania wstępne pompy ciepła zasilanej ciepłem przejścia fazowego wody". Chłodnictwo. (1-2) : 18-22. [2] Bogusław Zakrzewski, Wojciech Tuchowski. 2014. "Badania wstępne wodnej pompy ciepła pracującej w warunkach oblodzenia dolnego wymiennika ciepła". Chłodnictwo. (4) : 8-12. [3] Dyrektywa parlamentu Europejskiego i Rady 2009/28/WE z dnia 23 kwietnia 2009 r. w sprawie promowania stosowania energii ze źródeł odnawialnych zmieniająca i w następstwie uchylająca dyrektywy 2001/77/WE oraz 2003/30/WE. [4] Jan Szargut: "Termodynamika". Wydanie VII poprawione. Wydawnictwo Naukowe PWN, Warszawa 2013 [5] Rozporządzenie Ministra Gospodarki Rzeczpospolitej Polskiej z dnia 4 kwietnia 2014 roku w sprawie sposobu obliczania końcowego zużycia energii brutto ze źródeł odnawialnych oraz sposobu obliczania ilości energii elektrycznej i ciepła z takich źródeł. [6] Rozprawa doktorska dr inż. Wojciecha Tuchowskiego: "Badania eksperymentalne efektywności pompy ciepła wykorzystującej utajone ciepło zamarzania wody". Wydział Techniki Morskiej i Transportu, październik 2015. [7] Wiesław Pudlik: "Wymiana i Wymienniki Ciepła" - Politechnika Gdańska, Wydanie IV, Gdańsk 2008 [8] Wojciech Tuchowski, Bogusław Zakrzewski, Tomasz Łokietek. 2016. "Możliwości wykorzystania wodnych pomp ciepła". Chłodnictwo. (7-8) : 20-26. [9] Wojciech Tuchowski, Bogusław Zakrzewski. 2012. "Stanowisko badawcze wodnej pompy ciepła". Chłodnictwo. (7-8) : 6-9. [10] Wybrane Tablice Cieplne (materiały pomocnicze do ćwiczeń z Termodynamiki i Wymiany Ciepła), Politechnika Krakowska, Kraków Rys. 4. Wykres normalności reszt i wynik testu Shapiro-Wilka 2008.
Treść płatna
Jeśli masz wykupiony/przyznany dostęp -
zaloguj się
.
Skorzystaj z naszych propozycji zakupu!
Publikacja
e-Publikacja (format pdf) - nr 107668 "Praca wodnej pompy ciepła..."
licencja: Osobista
Produkt cyfrowy
10.00 zł
Do koszyka
Zeszyt
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA - e-zeszyt (pdf) 2017-7
licencja: Osobista
Produkt cyfrowy
30.00 zł
Do koszyka
Prenumerata
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA - prenumerata cyfrowa
licencja: Osobista
Produkt cyfrowy
Promocja
Nowość
360.00 zł
Do koszyka
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA - papierowa prenumerata roczna + wysyłka
licencja: Osobista
Szczegóły pakietu
Nazwa
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA - papierowa prenumerata roczna
432.00 zł brutto
400.00 zł netto
32.00 zł VAT
(stawka VAT 8%)
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA - pakowanie i wysyłka
42.00 zł brutto
34.15 zł netto
7.85 zł VAT
(stawka VAT 23%)
474.00 zł
Do koszyka
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA - PAKIET prenumerata PLUS
licencja: Osobista
Szczegóły pakietu
Nazwa
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA - PAKIET prenumerata PLUS (Prenumerata papierowa + dostęp do portalu sigma-not.pl + e-prenumerata)
552.00 zł brutto
511.11 zł netto
40.89 zł VAT
(stawka VAT 8%)
552.00 zł
Do koszyka
Zeszyt
2017-7
Czasopisma
ATEST - OCHRONA PRACY
AURA
AUTO MOTO SERWIS
CHEMIK
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
ODZIEŻ
OPAKOWANIE
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH