Czasopisma
Czasopisma
Czasopisma
ATEST - OCHRONA PRACY
ATEST - OCHRONA PRACY
AURA
AURA
AUTO MOTO SERWIS
AUTO MOTO SERWIS
CHEMIK
CHEMIK
CHŁODNICTWO
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
Czasopisma
Czasopisma
Czasopisma
GAZETA CUKROWNICZA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
OCHRONA PRZED KOROZJĄ
Czasopisma
Czasopisma
Czasopisma
ODZIEŻ
ODZIEŻ
OPAKOWANIE
OPAKOWANIE
PACKAGING REVIEW
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PAPIERNICZY
Czasopisma
Czasopisma
Czasopisma
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH
WOKÓŁ PŁYTEK CERAMICZNYCH
Menu
Menu
Menu
Prenumerata
Prenumerata
Publikacje
Publikacje
Drukarnia
Drukarnia
Kolportaż
Kolportaż
Reklama
Reklama
O nas
O nas
ui-button
Twój Koszyk
Twój koszyk jest pusty.
Niezalogowany
Niezalogowany
Zaloguj się
Zarejestruj się
Reset hasła
Czasopismo
|
PRZEGLĄD ELEKTROTECHNICZNY
|
Rocznik 2017 - zeszyt 6
An Algorithm for transformer hot spot temperature determining
10.15199/48.2017.06.32
Srdjan JOKIC
Danijel MIJIC
Petar MATIC
nr katalogowy: 106232
10.15199/48.2017.06.32
Streszczenie
This paper presents an algorithm for the winding temperature change estimation and the hot spot temperature determining of an oil filled power transformer. The proposed algorithm is based on the functional relation between the change of winding resistance and the measured oil temperature. The temperature changes approximation is based on the method of least squares. The proposed method is applied in the software for a field test instrument and verified by the field experiments.
Abstract
W artykule przedstawiono algorytm służący do szacowania zmian temperatury uzwojeń oraz wyznaczania temperatury najgorętszego miejsca (ang. hot spot) w transformatorze wypełnionym olejem. Proponowany algorytm oparty jest na funkcjonalnej zależności pomiędzy zmianą rezystancji uzwojenia a mierzoną temperaturą oleju. Aproksymacja zmiany temperatury bazuje na metodzie najmniejszych kwadratów. Zaproponowana metoda stosowana jest w oprogramowaniu przyrządu testującego i zweryfikowana została eksperymentalnie. (Algorytm do wyznaczania temperatury hot spotu transformatora)
Słowa kluczowe
algorithm
extrapolation
hot spot
temperature measurement
transformers.
Keywords
algorytm
ekstrapolacja
najgorętszy punkt
pomiar temperatury
transformatory.
Bibliografia
[1] Perez J., Fundamental principles of transformer thermal loading and protection, Conference for Protective Relay Engineers, TX. USA, March 29-April 1, (2010), 1-14 [2] IEC Std 60076-2, Power Transformers, Part 2: Temperature rise for liquid-immersed transformers, (2011) [3] IEC Std 60076-7, Power Transformers, Part 7: Loading guide for oil-immersed power transformers, (2009) [4] IEEE Std C57.12.90, Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers, (2010) [5] IEEE Std 1538-2000, "IEEE Guide for Determination of Maximum Winding Temperature Rise in Liquid-Filled Transformers," (2000) [6] Pierce L.W., An investigation of the thermal performance of an oil filled transformer winding, IEEE T. Power Deliver, 7 (1992), 1347-1358 [7] teNyenhuis E.G., Girgis R.S., Mechler G.F., Zhou G., Calculation of core hot-spot temperature in power and distribution transformers, IEEE T. Power Deliver, 17 (2002), 991-995 [8] Douglas D., Lawrence C., Templeton J., Factory Overload Testing of a Large Power Transformer, IEEE T Power Ap. Syst., 104 (1985), 2492-2500 [9] Miller S.J., The Method of Least Squares,. Math Brown, Providence: Brown University, (2006),1-7 [10] IEEE Std 62-1995. IEEE Guide for Diagnostic Field Testing of Electric Power Apparatus-Part 1, (2005) [11] Radosavljevic R.Lj., Popovic A., Milosavljevic V., Damjanovic M., Temperature Measurement of Primary Windings of Transformers in the Hydro-Electric Power Plant “Djerdap 1“ rated 380 MVA, 2x15,75 kV/420 kV, d5/d5/YN, OFWF, under Load after 30 years operation, CIGRE, Paris, (2004), A2-106, 1-8 [12] Sidi A., Interpolation at equidistant points by a sum of exponential functions, J. Approx. Theor. 34 (1982), 194-210 [13] IEC Std 60076-1, Power Transformers, Part 1: Temperature rise for liquid-immersed transformers, (2011), 87-89 [14] Aubin J., Langhame Y., Efect of oil viscosity on transformer loading capability at low ambient temperature, IEEE T. Power Deliver., 7 (1992), 516-524 [15] Susa D., Nordman H., A Simple Model for Calculating Transformer Hot-Spot Temperature, IEEE T. Power Deliver., 24 (2009), 1257-1265 [16] Pradhan M.K., Ramu T.S., Estimation of the Hottest Spot Temperature (HST) in Power Transformers Considering Thermal Inhomogeneity of the Windings, IEEE T. Power Deliver, 19 (2004), 1704-1712 [17] Taghikhani M.A., Power Transformer Winding Thermal Analysis Considering Load Conditions and Type of Oil, Int J. Mat. and Mech. Eng, 1 (2012), 109-113 [18] Kweon D.J., Koo K.S., Woo J.W., Kwak J.S., A Study on the Hot Spot Temperature in 154kV Power Transformers, J. Elec. Eng. Tech, 7 (2012), 312-319 [19] Radakovic Z., Feser K., A new method for the calculation of the hot-spot temperature in power transformers with onan cooling, IEEE T. Power Deliver, 18 (2003), 1284-1292 [20] Roizman O., Davydov V., Temperature rise test, IEEE TCM; Miami, FL, (2009), 1-25
Treść płatna
Jeśli masz wykupiony/przyznany dostęp -
zaloguj się
.
Skorzystaj z naszych propozycji zakupu!
Publikacja
e-Publikacja (format pdf) - nr 106232 "An Algorithm for transfor..."
licencja: Osobista
Produkt cyfrowy
10.00 zł
Do koszyka
Zeszyt
PRZEGLĄD ELEKTROTECHNICZNY - e-zeszyt (pdf) 2017-6
licencja: Osobista
Produkt cyfrowy
55.00 zł
Do koszyka
Prenumerata
PRZEGLĄD ELEKTROTECHNICZNY - prenumerata cyfrowa
licencja: Osobista
Produkt cyfrowy
Nowość
762.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS (Prenumerata papierowa + dostęp do portalu sigma-not.pl + e-prenumerata)
1002.00 zł brutto
927.78 zł netto
74.22 zł VAT
(stawka VAT 8%)
1002.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna + wysyłka
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna
960.00 zł brutto
888.89 zł netto
71.11 zł VAT
(stawka VAT 8%)
PRZEGLĄD ELEKTROTECHNICZNY - pakowanie i wysyłka
42.00 zł brutto
34.15 zł netto
7.85 zł VAT
(stawka VAT 23%)
1002.00 zł
Do koszyka
Zeszyt
2017-6
Czasopisma
ATEST - OCHRONA PRACY
AURA
AUTO MOTO SERWIS
CHEMIK
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
ODZIEŻ
OPAKOWANIE
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH