Czasopisma
Czasopisma
Czasopisma
ATEST - OCHRONA PRACY
ATEST - OCHRONA PRACY
AURA
AURA
AUTO MOTO SERWIS
AUTO MOTO SERWIS
CHEMIK
CHEMIK
CHŁODNICTWO
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
Czasopisma
Czasopisma
Czasopisma
GAZETA CUKROWNICZA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
OCHRONA PRZED KOROZJĄ
Czasopisma
Czasopisma
Czasopisma
ODZIEŻ
ODZIEŻ
OPAKOWANIE
OPAKOWANIE
PACKAGING REVIEW
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PAPIERNICZY
Czasopisma
Czasopisma
Czasopisma
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH
WOKÓŁ PŁYTEK CERAMICZNYCH
Menu
Menu
Menu
Prenumerata
Prenumerata
Publikacje
Publikacje
Drukarnia
Drukarnia
Kolportaż
Kolportaż
Reklama
Reklama
O nas
O nas
ui-button
Twój Koszyk
Twój koszyk jest pusty.
Niezalogowany
Niezalogowany
Zaloguj się
Zarejestruj się
Reset hasła
Czasopismo
|
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
|
Rocznik 2017 - zeszyt 1
Projekt systemu zdalnego monitorowania zmian ciśnienia tętniczego krwi
10.15199/13.2017.1.3
Krzysztof Sieczkowski
Tadeusz Sondej
Andrzej Dobrowolski
Robert Olszewski
nr katalogowy: 103745
10.15199/13.2017.1.3
W artykule przedstawiono projekt systemu, przeznaczonego do zdalnego i ciągłego monitorowania zmian ciśnienia tętniczego krwi oraz wyniki badań testowych. Przedstawiony system złożony jest z osobistego urządzenia pomiarowego, punktu dostępowego do sieci Internet oraz ogólnodostępnego serwera danych. Istotnym elementem projektowanego systemu jest metoda ciągłego pomiaru zmian ciśnienia krwi, polegająca na określaniu czasu propagacji fali tętna. Czas ten wyznaczany jest pomiędzy charakterystycznym punktem sygnału elektrokardiograficznego (EKG) i sygnału fotopletyzmograficznego (PPG). W artykule przedstawiono wyniki badań testowych, dotyczących wyznaczania punktów charakterystycznych sygnału EKG i PPG metodą autokorelacyjną oraz wyniki pomiaru zmian czasu propagacji fali tętna. Słowa kluczowe: nieinwazyjny ciągły pomiar ciśnienia krwi; opóźnienie fali tętna; monitorowanie zdrowia; systemy zdalnego monitorowania; telemedycyna.Według danych Głównego Urzędu Statystycznego (GUS), choroby układu krążenia są powodem niemal 49% (za rok 2015) zgonów w Polsce [1]. Przewiduje się, że do roku 2050, ten wskaźnik osiągnie wartość 51%. Zgony te głównie dotyczą (ponad 85%) osób w wieku 65 lat i więcej. Jedną z istotnych chorób układu krążenia jest nadciśnienie tętnicze (NT). Szacuje się, że NT dotyczy 80 milionów ludzi w U SA i miliarda na świecie, co daje tej jednostce chorobowej pierwsze miejsce w przyczynie utraty zdrowia i ponoszonych kosztach przez systemy zdrowotne [2]. Ciśnienie krwi zależy od wielu czynników i jest bardzo ważnym, a często krytycznym parametrem będącym emanacją stanu zdrowia. Jest więc jednocześnie bardzo czułą i specyficzną cechą diagnostyczną. Regularny pomiar ciśnienia tętniczego krwi i stosowanie odpowiednich leków może skutecznie zahamować rozwój choroby. Szczególnie ważne jest monitorowanie tego ciśnienia w życiu codziennym. Do pomiaru ciśnienia tętniczego krwi, najczęściej stosuje się nieinwazyjną metodę osłucho[...]
Bibliografia
[1] U rząd Statystyczny, Statystyka zgonów i umieralności z powodu chorób układu krążenia, 2016. [2] D. Mozaffarian, E.J. Benjamin,A.S. Go, D.K. Arnett, M.J. Blaha, M. Cushman, et al., American Heart Association Statistics Committee, Stroke Statistics Subcommittee, Heart disease and stroke statistics-2015 update: a report from the American Heart Association, Circulation, 131:e29-e322, 2015. [3] G. Ogedegbe, T. Pickering, Principles and techniques of blood pressure measurement, Cardiol Clin.; 28(4), pp. 571-586, 2010. [4] L. Peter, N. Noury, M. Cerny, A review of methods for non-invasive and continuous blood pressure monitoring: Pulse transit time method is promising?, IRBM, vol. 35(5), pp. 271-282, 2014. [5] D. Buxi, J.M. Redouté, M.R. Yuce, A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time, Physiological Measurement, vol. 36(3), pp. R1-R26, 2015. [6] M. Forouzanfar, S. Ahmad, I. Batkin, H.R. Dajani, V.Z. Groza, M. Bolic, Coefficient-Free Blood Pressure Estimation Based on Pulse Transit Time-Cuff Pressure Dependence, IEEE Transactions on Biomedical Engineering, vol. 60(7), pp. 1814-1824, 2013. [7] Webster J.G. (ed.), Medical instrumentation. Application and design, 4th edition, John Willey & Sons, 2010. [8] M. Elgendi, M. Jonkman, F. DeBoer, Heart Rate Variability and the Acceleration Plethysmogram Signals Measured at Rest, chapter in Biomedical Engineering Systems and Technologies, vol. 127, pp. 266-277, 2010. [9] F. Wadehn, Yue Zhao, H.-A. Loeliger, Heart rate estimation in photoplethysmogram signals using nonlinear model-based preprocessing, Computing in Cardiology Conference (CinC), pp. 633-636, 2015. [10] V. R. Pamula, M. Verhelst, Ch. Van Hoof, R.F. Yazicioglu, A novel feature extraction algorithm for on the sensor node processing of compressive sampled photoplethysmography signals, IEEE Sensors Conferences, pp. 1-4, 2015. [11] K. Sieczkowski, T. Sondej, A. Dobrowolski, R. Olszewski, Autocorrelation algorithm for determining a pulse wave delay, 20th Conference SPA 2016, Poznań, 21-23.09.2016, pp. 321-326 [12] K. Sieczkowski, T. Sondej, A Method for Real-time Data Acquisition Using Matlab Software, Mixed Design of Integrated Circuits & Systems (MIXDES), 23rd International Conference, p. 437-442, 2016. [13] NIBScan, Hospital Grade Miniature NonInvasive Blood Pressure OEM Module for Professional Applications, Data Sheet Version 1.7, Medlab GmbH, 2016.
Treść płatna
Jeśli masz wykupiony/przyznany dostęp -
zaloguj się
.
Skorzystaj z naszych propozycji zakupu!
Publikacja
e-Publikacja (format pdf) - nr 103745 "Projekt systemu zdalnego ..."
licencja: Osobista
Produkt cyfrowy
10.00 zł
Do koszyka
Zeszyt
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA - e-zeszyt (pdf) 2017-1
licencja: Osobista
Produkt cyfrowy
35.00 zł
Do koszyka
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA - e-zeszyt (pdf) 2017-10
licencja: Osobista
Produkt cyfrowy
35.00 zł
Do koszyka
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA - e-zeszyt (pdf) 2017-11
licencja: Osobista
Produkt cyfrowy
35.00 zł
Do koszyka
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA - e-zeszyt (pdf) 2017-12
licencja: Osobista
Produkt cyfrowy
35.00 zł
Do koszyka
Prenumerata
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA - prenumerata cyfrowa
licencja: Osobista
Produkt cyfrowy
Nowość
420.00 zł
Do koszyka
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA - papierowa prenumerata roczna + wysyłka
licencja: Osobista
Szczegóły pakietu
Nazwa
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA - papierowa prenumerata roczna
528.00 zł brutto
488.89 zł netto
39.11 zł VAT
(stawka VAT 8%)
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA - pakowanie i wysyłka
42.00 zł brutto
34.15 zł netto
7.85 zł VAT
(stawka VAT 23%)
570.00 zł
Do koszyka
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA - PAKIET prenumerata PLUS
licencja: Osobista
Szczegóły pakietu
Nazwa
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA - PAKIET prenumerata PLUS (Prenumerata papierowa + dostęp do portalu sigma-not.pl + e-prenumerata)
636.00 zł brutto
588.89 zł netto
47.11 zł VAT
(stawka VAT 8%)
636.00 zł
Do koszyka
Zeszyt
2017-1
Czasopisma
ATEST - OCHRONA PRACY
AURA
AUTO MOTO SERWIS
CHEMIK
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
ODZIEŻ
OPAKOWANIE
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH