Czasopisma
Czasopisma
Czasopisma
ATEST - OCHRONA PRACY
ATEST - OCHRONA PRACY
AURA
AURA
AUTO MOTO SERWIS
AUTO MOTO SERWIS
CHEMIK
CHEMIK
CHŁODNICTWO
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
Czasopisma
Czasopisma
Czasopisma
GAZETA CUKROWNICZA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
OCHRONA PRZED KOROZJĄ
Czasopisma
Czasopisma
Czasopisma
ODZIEŻ
ODZIEŻ
OPAKOWANIE
OPAKOWANIE
PACKAGING REVIEW
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PAPIERNICZY
Czasopisma
Czasopisma
Czasopisma
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH
WOKÓŁ PŁYTEK CERAMICZNYCH
Menu
Menu
Menu
Prenumerata
Prenumerata
Publikacje
Publikacje
Drukarnia
Drukarnia
Kolportaż
Kolportaż
Reklama
Reklama
O nas
O nas
ui-button
Twój Koszyk
Twój koszyk jest pusty.
Niezalogowany
Niezalogowany
Zaloguj się
Zarejestruj się
Reset hasła
Czasopismo
|
PRZEGLĄD ELEKTROTECHNICZNY
|
Rocznik 2016 - zeszyt 10
Zastosowanie metody UHF do detekcji i analizy zjawiska wyładowań niezupełnych
10.15199/48.2016.10.14
Michał KUNICKI
nr katalogowy: 101201
10.15199/48.2016.10.14
W artykule przedstawiono możliwości jakie obecnie daje zastosowanie metody ultra wysokich częstotliwości (UHF) do detekcji i analizy zjawiska wyładowań niezupełnych (WNZ) w izolacji olejowej. Badania prowadzone były w warunkach laboratoryjnych na trzech wybranych modelowych źródłach generujących WNZ w oleju elektroizolacyjnym: układ ostrze-ostrze, układ powierzchniowy i układ wieloostrze-płyta. Dokonano szczegółowej analizy wyników pomiarowych oraz na tej podstawie zaproponowano metodę identyfikacji wybranych form jednoźródłowych WNZ. Abstract. Various contemporary application abilities of the ultra-high frequency (UHF) method for partial discharge (PD) detection and analysis in oil insulation are presented in the paper. Three different spark gap configuration are selected for PD modeling in oil insulation: point to point, surface type and multipoint to plate. All research are proceeded under laboratory conditions. Identification methodology of the selected single-source PD models is proposed on the grounds of the detailed measurement results analysis. (Partial discharge detection and analysis using UHF method). Słowa kluczowe: wyładowania niezupełne, metoda UHF, metoda niekonwencjonalna, olej elektroizolacyjny. Keywords: partial discharge, UHF method, unconventional method, insulation oil. Wstęp Zjawisko wyładowań niezupełnych (WNZ) jest bardzo powszechnym i niekorzystnym aspektem związanym z degradacją izolacji urządzeń wysokonapięciowych. Znaczna cześć poważnych awarii związanych z dystrybucją zasilania powiązana jest pośrednio lub bezpośrednio ze zjawiskiem WNZ [1]. Odpowiednio wczesna detekcja i lokalizacja degradacji układów izolacyjnych kluczowych urządzeń elektroenergetycznych, takich jak generatory czy transformatory, pozwala zaplanować proces remontowy oraz ewentualne odstawienie i zastąpienie konkretnej jednostki w systemie elektroenergetycznym, w taki sposób aby odbyło się to bez wpływu na odbiorcę oraz było procesem w pe[...]
Bibliografia
[1] Hapeez M. S., Abidin A. F., Hashim H., Hamzah M. K., Hamzah N. R., Analysis and Classification of Different Types of Partial Discharges by Harmonic Orders, Elektronika Ir Elektrotechnika, 19 (2013), n.9, 35-41 [2] Yaacob M. M., Alsaedi M. A., Rashed J. R., Dakhil A. M., Atyah S. F., Review on Partial Discharge Detection Techniques Related to High Voltage Power Equipment Using Different Sensors, Photonic sensors, 4 (2014), n.4, 325-337 [3] Kunicki M., Cichoń A., Characterization of surface type partial discharges using electrical , acoustic emission and UHF methods, Measurement Automation Monitoring, 61 (2015), n.01, 12-15 [4] Boczar T., Cichoń A., Borucki S., Diagnostic expert system of transformer insulation systems using the acoustic emission method, IEEE Transactions on Dielectrics and Electrical Insulation, 21 (2014), n.2, 854-865 [5] Kunicki M., Cichoń A., Borucki S., Study on Descriptors of Acoustic Emission Signals Generated by Partial Discharges under Laboratory Conditions and in On-Site Electrical Power Transformer, Archives of Acoustics, 41 (2016), n.2, 265-276 [6] Berger P., Cichoń A., Deskryptory sygnałów emisji akustycznej generowanych przez nowy podobciążeniowy przełącznik zaczepów zainstalowany w transformatorze elektroenergetycznym, Przeglad Elektrotechniczny, 90 (2014), n.1, 199-201 [7] Sikorski W., Walczak K., PDtracker - system monitoringu wyładowań niezupełnych w transformatorze energetycznym, Przeglad Elektrotechniczny, 90 (2014), n.10, 45-49 [8] Equipment P., Equipment P., Equipment P., Based on the Fourier Transform Infrared, in IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Montevideo, 2014, 14-18 [9] Zhang X., Liu H., Ren J., Li J., Li X., Fourier transform infrared spectroscopy quantitative analysis of SF6 partial discharge decomposition components, Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy, 136 (2015), 884- 889 [10] Yan J., Liao R., Yang L., Li J., Liu B., Product analysis of partial discharge damage to oil-impregnated insulation paper, Applied Surface Science, 257 (2011), n.13, 5863-5870 [11] Amin E. M., Karmakar N. C., A Passive RF Sensor for Detecting Simultaneous Partial Discharge Signals Using Time- Frequency Analysis, IEEE Sensors Journal, 16 (2016), n.8, 2339-2348 [12] Müller A., Beltle M., Correlation of DGA, UHF PD Measurement and Vibration Data for Power Transformer Monitoring, in Symposium on High Voltage Engineering, Hannover, 2011 [13] Wang Z., Yi X., Wang X., Li S., Hinshaw J. V., Noakhes J., Comparison between online and laboratory measurements of fault gases for mineral oil and natural ester, International Journal on Electrical Engineering and Informatics, 5 (2013), n.2, 173-181 [14] Duval M., Lamarre L., The Duval Pentagon — A New Complementary Tool for the Interpretation of Dissolved Gas Analysis in Transformers, IEEE Electrical Insulation Magazine, 30 (2014), n.6, 1-4 [15] Sipahutar T. F., Kemma A. A., Pattanadech N., Pratomosiwi F., Suwarno, Muhr M., Effect of Test Method and Needle Plane Configuration on Partial Discharge Inception Voltage Measurement of Mineral Oil based on Weibull Analysis, Procedia Technology, 11 (2013), 411-418 [16] Cavallini A., Montanari G. C., Tozzi M., PD apparent charge estimation and calibration: A critical review, IEEE Transactions on Dielectrics and Electrical Insulation, 17 (2010), n.1, 198-205 [17] Pompili M., Bartnikas R., On partial discharge measurement in dielectric liquids, IEEE Transactions on Dielectrics and Electrical Insulation, 19 (2012), n.5, 1476-1481 [18]Kunicki M., Cichoń A., Time and frequency domain analysis of partial discharges using electrical method, Measurement Automation Monitoring, 62 (2016), n.2, 72-77 [19] Reid A. J., Judd M. D., Duncan G., Simultaneous measurement of partial discharge using TEV, IEC60270 and UHF techniques, Conference Record of IEEE International Symposium on Electrical Insulation, (2012), 439-442 [20] Zhang X. X., Tang J. Z., Tang J., Chen Y., Xie Y. B., Relationship between UHF PD Detection and Apparent Charge Quantity of Metal Protrusion in Air, Przeglad Elektrotechniczny, 88 (2012), n.4A, 266-270 [21] Sarathi R., Reid A. J., Judd M. D., Partial discharge study in transformer oil due to particle movement under DC voltage using the UHF technique, Electric Power Systems Research, 78 (2008), n.11, 1819-1825 [22] Zheng S., Li C., Tang Z., Chang W., He M., Location of PDs inside transformer windings using UHF methods, IEEE Transactions on Dielectrics and Electrical Insulation, 21 (2014), n.1, 386-393 [23] Robles G., Albarracan R., Martinez-Tarifa J., Shielding effect of power transformers tanks in the ultra-high-frequency detection of partial discharges, IEEE Transactions on Dielectrics and Electrical Insulation, 20 (2013), n.2, 678-684 [24] Asai M., Nishizawa K., Hayakawa N., Endo F., Yoshida M., Uchida K., Okubo H., Detail Analysis of Particle-Initiated Partial Discharges in Sf 6 Gas for Condition Monitoring of Gis, in 16th International Symposium on High Voltage Engineering, Johannesburg, 2009, 1-5 [25] Coenen S., Tenbohlen S., Location of PD sources in power transformers by UHF and acoustic measurements, IEEE Transactions on Dielectrics and Electrical Insulation, 19 (2012), n.6, 1934-1940
Treść płatna
Jeśli masz wykupiony/przyznany dostęp -
zaloguj się
.
Skorzystaj z naszych propozycji zakupu!
Publikacja
e-Publikacja (format pdf) - nr 101201 "Zastosowanie metody UHF d..."
licencja: Osobista
Produkt cyfrowy
10.00 zł
Do koszyka
Zeszyt
PRZEGLĄD ELEKTROTECHNICZNY - e-zeszyt (pdf) 2016-10
licencja: Osobista
Produkt cyfrowy
55.00 zł
Do koszyka
Prenumerata
PRZEGLĄD ELEKTROTECHNICZNY - prenumerata cyfrowa
licencja: Osobista
Produkt cyfrowy
Nowość
762.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - PAKIET prenumerata PLUS (Prenumerata papierowa + dostęp do portalu sigma-not.pl + e-prenumerata)
1002.00 zł brutto
927.78 zł netto
74.22 zł VAT
(stawka VAT 8%)
1002.00 zł
Do koszyka
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna + wysyłka
licencja: Osobista
Szczegóły pakietu
Nazwa
PRZEGLĄD ELEKTROTECHNICZNY - papierowa prenumerata roczna
960.00 zł brutto
888.89 zł netto
71.11 zł VAT
(stawka VAT 8%)
PRZEGLĄD ELEKTROTECHNICZNY - pakowanie i wysyłka
42.00 zł brutto
34.15 zł netto
7.85 zł VAT
(stawka VAT 23%)
1002.00 zł
Do koszyka
Zeszyt
2016-10
Czasopisma
ATEST - OCHRONA PRACY
AURA
AUTO MOTO SERWIS
CHEMIK
CHŁODNICTWO
CIEPŁOWNICTWO, OGRZEWNICTWO, WENTYLACJA
DOZÓR TECHNICZNY
ELEKTROINSTALATOR
ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA
GAZETA CUKROWNICZA
GAZ, WODA I TECHNIKA SANITARNA
GOSPODARKA MIĘSNA
GOSPODARKA WODNA
HUTNIK - WIADOMOŚCI HUTNICZE
INŻYNIERIA MATERIAŁOWA
MASZYNY, TECHNOLOGIE, MATERIAŁY - TECHNIKA ZAGRANICZNA
MATERIAŁY BUDOWLANE
OCHRONA PRZECIWPOŻAROWA
OCHRONA PRZED KOROZJĄ
ODZIEŻ
OPAKOWANIE
PACKAGING REVIEW
POLISH TECHNICAL REVIEW
PROBLEMY JAKOŚCI
PRZEGLĄD ELEKTROTECHNICZNY
PRZEGLĄD GASTRONOMICZNY
PRZEGLĄD GEODEZYJNY
PRZEGLĄD MECHANICZNY
PRZEGLĄD PAPIERNICZY
PRZEGLĄD PIEKARSKI I CUKIERNICZY
PRZEGLĄD TECHNICZNY. GAZETA INŻYNIERSKA
PRZEGLĄD TELEKOMUNIKACYJNY - WIADOMOŚCI TELEKOMUNIKACYJNE
PRZEGLĄD WŁÓKIENNICZY - WŁÓKNO, ODZIEŻ, SKÓRA
PRZEGLĄD ZBOŻOWO-MŁYNARSKI
PRZEMYSŁ CHEMICZNY
PRZEMYSŁ FERMENTACYJNY I OWOCOWO-WARZYWNY
PRZEMYSŁ SPOŻYWCZY
RUDY I METALE NIEŻELAZNE
SZKŁO I CERAMIKA
TECHNOLOGIA I AUTOMATYZACJA MONTAŻU
WIADOMOŚCI ELEKTROTECHNICZNE
WOKÓŁ PŁYTEK CERAMICZNYCH