Wyniki 1-3 spośród 3 dla zapytania: authorDesc:"WOJCIECH GAWLIK"

Prace z kondensatem Bosego-Einsteina atomów rubidu w Krajowym Laboratorium Fizyki Atomowej, Molekularnej i Optycznej

Czytaj za darmo! »

2 marca 2007 roku grupa fizyków z kilku polskich ośrodków pracująca w Krajowym Laboratorium Fizyki Atomowej, Molekularnej i Optycznej (KL FAMO) w Toruniu otrzymała pierwszy w Polsce kondensat Bosego-Einsteina atomów rubidu 87. Zespół tworzyli fizycy z Uniwersytetu Jagiellońskiego (Wojciech Gawlik, Andrzej Noga, Jerzy Zachorowski), Uniwersytetu Mikołaja Kopernika w Toruniu (Franciszek Bylicki[...]

Towards optical atomic clock and metrology with cold strontium atoms


  Techniques of laser cooling and trapping of atoms and ions have opened new possibilities for measurements with ultimate accuracy. The almost full reduction of Doppler broadening and precision control over external degrees of freedom of atoms and ions enabled improvement of accuracy of time and frequency standards. It should be noted that present realizations of the standards of the second - the atomic fountain clocks can be realized only with cold atoms. Similarly, cold atoms and ions are at the heart of the optical atomic clocks, which open the way to the next generation of time and frequency standard (see review [1]). Optical clocks have already surpassed the accuracy of microwave clocks [2, 3] and reached inaccuracies below 10-15 with expected control of systematic effects at the 10-18 level. Although the standards using ions and atoms offer similar parameters, they have important technical differences: ions can be relatively easily trapped with electromagnetic forces and cooled to zero point of motion but strong ion-ion interactions limit the number of ions in a trap, hence most advanced experiments are performed with single ions. Neutral atoms are more difficult to trap, but offer the possibility of simultaneous measurements of large numbers of atoms increasing the S/N ratio. Moreover, atoms can be additionally confined in an optical lattice, which limits the atom-atom interactions without perturbing the clock transition [4, 5, 6]. Strontium atoms with two electron in the s shell in the ground state (total angular momentum J = 0) are very interesting for the metrology purpose. Simple energy level structure (see Fig. 1) and presence of a strong optical transition 1S0 - 1P1 opens the possibility to cool effectively atoms and trap them. Transition between the singlet ground and the lowest triplet states enables further cooling of atoms (transition 1S0 - 3P1), after which the ultra-narrow intercombination transition 1S0 - 3[...]

Nowa metoda magnetometrii optycznej

Czytaj za darmo! »

Współcześnie wykorzystywanych jest kilka metod pomiarów pola magnetycznego. Jedna z nich eksploatuje magnetyczne właściwości materiałów. Przykładami urządzeń, w których jest ona zastosowana, są gigantyczne magnetorezystory [1] i magnetometry oparte o magnetyczne złącza tunelujące [2]. Tego typu metody pozwalają na osiągnięcie czułości pomiarów pól magnetycznych w przedziale od 1 nT/Hz1/2 do [...]

 Strona 1